Страница 2: ...and limits No part of this publication may be reproduced stored in a retrieval system or transmitted in any form or by any means mechanical photocopying recording or otherwise Replace battery with TOS...

Страница 3: ...uage Setting the Minutes Printing 1 60 or 1 100 printing Setting the 12 24 HOUR format Setting the Daylight Saving Time D S T Setting the starting date of daylight saving time Setting the ending date...

Страница 4: ...possibly leading to an electric shock Do not use any voltage of the power source other than designated Do not share a single outlet with another plug These may lead to fire or shock hazards Do not da...

Страница 5: ...ord may be damaged possibly leading to a fire or electric shock Remove the line cord plug from the outlet before transferring the unit or it may damage the cord possibly leading to a fire or electric...

Страница 6: ...e front or back of the card thereby ensuring that the time is printed on the correct side of a monthly card If the closing date for payroll processing does not fall on the end of a month the unit can...

Страница 7: ...s Operation Manual Wall Mount Screws Ribbon Cassette Keys Daylight saving time indication Display Key hole Cover Display Control button Card slot Wall mounting hole Day of the week indication Current...

Страница 8: ...to tighten the ribbon 3 Place the ribbon cassette inside the time recorder as shown in the figure Keep on pushing in the ribbon cassette until the clasps at both sides catch and you hear a pop sound...

Страница 9: ...is placed behind the ribbon mask see the figure on the right 4 Precautions to take when replacing the ribbon 6 5 Replace the cover by fitting the plugs at both sides of the cover into the holes locat...

Страница 10: ...come off if used on other materials Install wall mount screws supplied into a wall 3 94 inches 10 cm apart Be sure to keep about 0 12 inch 3 mm of the screw head out of the wall Environmental Conditio...

Страница 11: ...easy to operate the unit Just insert a time card The card is then automatically pulled in printed and then ejected The unit is designed to print on the first column when no time table program is set...

Страница 12: ...o the following page for the details of each setting 4 After the setting has been completed fit the plugs at the lower sides of the cover into the holes of the unit 5 Pull back the cover while returni...

Страница 13: ...T button and position the mark at the upper side of the display next to the first item from the left PAY PERIOD If the case is monthly closing push the SET button At that moment the flashing of the di...

Страница 14: ...y and the setting is now completed SELECT CHANGE SET SELECT CHANGE SET IN OUT IN OUT IN OUT 1 2 3 4 5 6 7 Today Tuesday January 9 2001 Set closing day Sunday January 14 2001 1 MONTHLY 2 WEEKLY 3 BI WE...

Страница 15: ...ton to set the left hand number of the display at 3 and then push the SET button At that moment the flashing of the display will change to the right hand number 3 Push the SET button to finish the set...

Страница 16: ...ing the Minute for example from 8 minutes to 9 minutes Push the CHANGE button to set Minute at 09 and then push the SET button Now the minutes of 9 have been set At that moment the flashing of the dis...

Страница 17: ...ber has been set At that moment the flashing of the display will change from Month to Date 4 Change Date for example from 20 to 21 Push the CHANGE button to set Date at 21 and then push the SET button...

Страница 18: ...because Minute is not to be changed Now 00 minute has been set At that moment Minute on the display will change from flashing to steady and the setting of the day advance time is now completed DAY AD...

Страница 19: ...rint style can be selected from the following six styles Setting the Print Style Order Options Line Format Print Example Monday 21 3 30 p m 1 DD 24HOUR 2 D O W 24HOUR 3 24HOUR LARGE FONT 4 12HOUR 5 DD...

Страница 20: ...dy and the setting is now completed LANGUAGE SELECT CHANGE SET SELECT CHANGE SET 1 ENGLISH 2 SPANISH 3 GERMAN 4 FRENCH 5 ITALIAN 6 PORTUGUESE LANGUAGE 1 ENGLISH 2 SPANISH 3 GERMAN 4 FRENCH 5 ITALIAN 6...

Страница 21: ...2 if 1 100 printing is desired 2 Push the SET button to finish the setting At that moment the display will change from flashing to steady and the setting is now completed Setting the Minutes Printing...

Страница 22: ...24 HOUR For example set 2 if 24 HOUR is desired 2 Push the SET button to end the setting At that moment the display will change from flashing to steady and the setting is now completed DISPLAY SELECT...

Страница 23: ...he above the unit remembers the start date as the last Sunday of March and the end date as the last Sunday of October Once set the unit automatically updates the settings every year thereafter No furt...

Страница 24: ...the setting of the month is completed At that moment the flashing of the display will change from Month to Date 4 Set the date when the daylight saving time starts Push the CHANGE button to set the da...

Страница 25: ...to and push the SET button twice to change the display as shown in the left figure This cancels the daylight saving time settings Setting the ending date of daylight saving time Example If daylight s...

Страница 26: ...lly Work day ends at 17 00 Automatic column shift and Special mark printing cannot be set simultaneously Day advance time Example 5 00 17 00 5 00 Next day Print in Column 1 Print in Column 4 P1 The fo...

Страница 27: ...ng will change from Hour to Minute 4 Push the CHANGE button to move the Minutes to 00 Then push the SET button The flashing will change from Minute to the of Column 1 PROGRAM SELECT CHANGE SET Minute...

Страница 28: ...00 Day advance time 17 00 5 00 5 00 9 00 12 00 Next day Standard printing Standard printing Special mark printing Print Column 25 1 DD 24HOUR 2 D O W 24HOUR 3 24HOUR LARGE FONT 4 12HOUR 5 DD 12HOUR 6...

Страница 29: ...from Hour to Minute PROGRAM SELECT CHANGE SET ON OFF Hour Minute Minute ON OFF Hour ON OFF Hour PROGRAM SELECT CHANGE SET PROGRAM SELECT CHANGE SET The following is the time table based on above case...

Страница 30: ...Push the SET button to flash P1 Then push the CHANGE button to flash P2 7 Follow the same procedure from to to set 17 00 8 Push the CHANGE button to position the under OFF of Special mark ON OFF The p...

Страница 31: ...ECT CHANGE SET PROGRAM SELECT CHANGE SET To confirm the programs that have been set flash Program No and push the CHANGE button To delete a program flash Hour and push the CHANGE button Change the dis...

Страница 32: ...leted and will revert to the factory defaults when the reset switch is pushed To make new settings please refer to SETTING To return all settings to their factory defaults push the reset switch with a...

Страница 33: ...sition the battery as shown in the figure to the left The connector cord should be on the right side as shown in the figure Connect the connector Tuck away the connector cord into the open space in th...

Страница 34: ...inserted is wrong The card is not pulled in properly The card is not pulled in properly Card sensor error Cannot print The printer motor or home position sensor is not normal The card is not pulled in...

Страница 35: ...mulative power failure hours after the date of shipment Optional Ni Cd battery 100 time printing or 24 hours Temperature 5 to 45 C 25 to 113 F Humidity 20 to 80 RH no condensation The unit operates no...

Страница 36: ...9 TIME CARD SPECIFICATIONS Monthly Card Front Side S Card double sided Reverse Side Note Recommended Paper Thickness 0 45 0 05mm 1 2 33...

Страница 37: ...Weekly Card Bi Weekly Card 34...

Страница 38: ...MEMO 35...

Страница 39: ...Printed in Japan Q0100 6120 3 0107 70A01...