Seifert 580320001 Скачать руководство пользователя страница 3

Version Nr. 1-5 - 13.06.2022

Doc. No. 99580320001

3 / 15

Disregarding the instruction manual
Operating error
Inappropriate work on or with the unit
The use of non-specified spare parts and accessories
Unauthorised modifications or changes to the unit by the user or his personnel

The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main
contractual agreement. Claims for damages on any grounds are excluded.

3. Safety instructions

Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into
operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited
from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of
the unit. 
Please note that before starting to work on or with the unit, a procedure must be carried out inside the cabinet
on which the unit is to be mounted.
Before commencing work inside the cabinet, the control cabinet manufacturer's instruction must be read with
regards to:

Safety instructions.
Instructions on taking the cabinet out of operation.
Instructions on the prevention of unauthorised cabinet reconnection.

The electric equipment meets the valid safety regulations. One can find dangerous voltages (above 50 V AC or
above 100 V DC)

Behind the control cabinet doors.
On the power supply in the unit housing.

The unit has to be operated according to the type plate and the wiring diagram, and must be protected
externally from overloading and electrical faults via suitable protective devices.

Danger through incorrect work on the unit
The unit can only be installed and maintained by technical competent and qualified personnel,
using only supplied material according to the supplied instructions.
 

Danger from electrical voltage
Only specialised personnel are allowed to maintain and clean the unit. The personnel must
ensure that for the duration of the maintenance and cleaning, the unit is disconnected from
the electrical supply.
 
Attention
Damage to the unit through the use of inappropriate cleaning materials. Please do not use
aggressive cleaning material.
 
Instruction
Damage to the environment through unauthorised disposal. All spare parts and associated
material must be disposed according to the environmental laws.
 

Содержание 580320001

Страница 1: ...3 4 Settings 4 5 Functional principle 7 6 Technical data 7 7 Performance graph 8 8 Mounting 9 9 Mounting Principle 10 10 Cut out dimensions 11 11 Dimensions H x W x D 12 12 Wiring diagram 13 13 Taking...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates e...

Страница 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...

Страница 4: ...plies to external ambient air as the coolant In air to air heat exchangers the internal temperature of the control cabinet cannot be cooler than the ambient temperature There are natural limits to the...

Страница 5: ...slowly and display should show St2 and then the pre set value of St2 default 5 C 41 F 2 Reach the desired value by using or 3 Press SET again to save the new value of St2 Setting temperature unit low...

Страница 6: ...ant Notes Whilst programming if no button is pressed for 10 seconds the display starts ashing and after 1 minute returns to the main display without saving changes To increase scrolling speed press an...

Страница 7: ...impeded Ambient air circuit 147 324 cfm Cabinet air circuit 150 324 cfm Mounting Wall mounted Housing Material Mild steel powder coated Dimension H x W x D 29 5 x 10 x 5 95 inch Weight 26 5 lbs Voltag...

Страница 8: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 8 15 7 Performance graph...

Страница 9: ...absolute thoroughness to ensure that the unit works perfectly Transport damage check On delivery the carton containing the unit must be examined for signs of transport damage Any transport damage to...

Страница 10: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 10 15 9 Mounting Principle 1 Heat exchanger 2 Mounting gasket 3 Slotted stud M6 x 1 inch 4 Enclosure 5 Washer A6 4 6 M6 Lock nut...

Страница 11: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 11 15 10 Cut out dimensions...

Страница 12: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 12 15 11 Dimensions H x W x D...

Страница 13: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 13 15 12 Wiring diagram Power connector 1 L 2 N 3 PE 4 Alarm NO 5 Alarm COM 6 Alarm NC 7 Door contact 8 Door contact...

Страница 14: ...aintenance and cleaning must be carried out by specialists electricians The personnel must ensure that for the duration of this work the unit and the cabinet are disconnected from the electrical suppl...

Страница 15: ...packing The unit must be protected su ciently by shock absorbing padding hard foam corner pieces strips or cardboard corner pieces 17 Parts supplied Spare parts Accessories 1 x Heat exchanger 1 x Inst...