Seifert 580320001 Скачать руководство пользователя страница 15

Version Nr. 1-5 - 13.06.2022

Doc. No. 99580320001

15 / 15

16. Transport & Storage

Malfunction due to transport damage
On delivery the carton containing the unit must be examined for signs
of transport damage. Any transport damage to the carton could
indicate that the unit itself has been damaged in transit which in the
worst case could mean that the unit will not function.

Storage conditions

The unit can only be stored in locations which meet the following conditions:        

Temperature range: 104°F to 158°F
Relative humidity (at 77°F): max. 95%

Returning the unit

Damage to the unit through incorrect transport.
To avoid transport damage the unit should be returned in the original
packing or in a packing case and must be strapped to a pallet!

If the unit cannot be returned in the original packing please ensure that:

A space of at least 30 mm. must be maintained at all points between the unit and the external packing.
The unit must be firmly fixed in the packing.
The unit must be protected sufficiently by shock absorbing padding (hard foam corner pieces, strips or
cardboard corner pieces).

17. Parts supplied / Spare parts / Accessories

1 x Heat exchanger
1 x Instruction manual
1 x EC Declaration
6 x Slotted Studs M6 * 25
6 x Washers A6,4 DIN125
6 x Lock nuts M6 DIN 985
1 x Tight tape
1 x Drain connector
1 x O-ring

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems AG

Seifert Systems GmbH

Seifert Systems Ltd.

Seifert Systems Inc.

Seifert Systems Pty Ltd.

Albert-Einstein-Str. 3

HF09/10 

Wilerstrasse 16

Bärnthal 1

Rep. Office

75 Circuit Drive

105 Lewis Road

 

Hal-Far Industrial Estate

 

 

 

North Kingstown

Wantirna South

42477 Radevormwald

Birzebbuga, BBG 3000

4563 Gerlafingen

4901 Ottnang

26100 Cremona

RI 02852

3152 Victoria

Germany

Malta

Switzerland

Austria

Italy

USA

Australia

Tel.+49 2195 68994-0

Tel.+356 2220 7000

Tel.+41 32 675 35 51

Tel.+43 7676 20712 0

Tel.+39 349 259 4524

Tel.+1 401-294-6960

Tel.+61 3 98 01 19 06

[email protected] [email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

Содержание 580320001

Страница 1: ...3 4 Settings 4 5 Functional principle 7 6 Technical data 7 7 Performance graph 8 8 Mounting 9 9 Mounting Principle 10 10 Cut out dimensions 11 11 Dimensions H x W x D 12 12 Wiring diagram 13 13 Taking...

Страница 2: ...instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates e...

Страница 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...

Страница 4: ...plies to external ambient air as the coolant In air to air heat exchangers the internal temperature of the control cabinet cannot be cooler than the ambient temperature There are natural limits to the...

Страница 5: ...slowly and display should show St2 and then the pre set value of St2 default 5 C 41 F 2 Reach the desired value by using or 3 Press SET again to save the new value of St2 Setting temperature unit low...

Страница 6: ...ant Notes Whilst programming if no button is pressed for 10 seconds the display starts ashing and after 1 minute returns to the main display without saving changes To increase scrolling speed press an...

Страница 7: ...impeded Ambient air circuit 147 324 cfm Cabinet air circuit 150 324 cfm Mounting Wall mounted Housing Material Mild steel powder coated Dimension H x W x D 29 5 x 10 x 5 95 inch Weight 26 5 lbs Voltag...

Страница 8: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 8 15 7 Performance graph...

Страница 9: ...absolute thoroughness to ensure that the unit works perfectly Transport damage check On delivery the carton containing the unit must be examined for signs of transport damage Any transport damage to...

Страница 10: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 10 15 9 Mounting Principle 1 Heat exchanger 2 Mounting gasket 3 Slotted stud M6 x 1 inch 4 Enclosure 5 Washer A6 4 6 M6 Lock nut...

Страница 11: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 11 15 10 Cut out dimensions...

Страница 12: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 12 15 11 Dimensions H x W x D...

Страница 13: ...Version Nr 1 5 13 06 2022 Doc No 99580320001 13 15 12 Wiring diagram Power connector 1 L 2 N 3 PE 4 Alarm NO 5 Alarm COM 6 Alarm NC 7 Door contact 8 Door contact...

Страница 14: ...aintenance and cleaning must be carried out by specialists electricians The personnel must ensure that for the duration of this work the unit and the cabinet are disconnected from the electrical suppl...

Страница 15: ...packing The unit must be protected su ciently by shock absorbing padding hard foam corner pieces strips or cardboard corner pieces 17 Parts supplied Spare parts Accessories 1 x Heat exchanger 1 x Inst...

Отзывы: