8. Mounting Principle
Страница 1: ...3 Safety instructions 3 4 Technical functions 4 5 Technical data 4 6 Performance Graph 5 7 Mounting 6 8 Mounting Principle 7 9 Dimensions H x W x D 8 10 Electrical connection 9 11 Wiring diagram 10 12...
Страница 2: ...e instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates...
Страница 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...
Страница 4: ...emperature sensitive components The characteristic graph shown in the section Performance graph applies to external ambient air as the coolant In air to air heat exchangers the internal temperature of...
Страница 5: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 5 14 6 Performance Graph T Temperature di erence between ambient and internal temperature P heat exchanger performance...
Страница 6: ...te thoroughness to ensure that the unit works perfectly Transport damage check On delivery the carton containing the unit must be examined for signs of transport damage Any transport damage to the car...
Страница 7: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 7 14 8 Mounting Principle...
Страница 8: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 8 14 9 Dimensions H x W x D...
Страница 9: ...er technical data Connecting the alarm and door contact interface To avoid unnecessary run time the heat exchanger can be switched on and o through the door contact There is also an alarm contact that...
Страница 10: ...ommon 3 Pink NC 4 not connected Connector J3 J5 J7 J9 Molex mini t jr 2 pole capacitor 1 Brown 2 Blue Connector J11 Molex KK 2 pole Door contact 1 Brown ON 2 Grey ON Connector J18 19 Molex mini t jr 2...
Страница 11: ...31 5 A T LED D3 5 7 9 Fuse OK LED D23 25 27 29 Fan OK green LED D24 26 28 30 Fan FAULT red Test buttons 0 10 sec All fans ON 10 20 sec Fan 1 ON fans 2 3 4 OFF 20 30 sec Fans 1 2 ON Fans 3 4 OFF 30 40...
Страница 12: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 12 14...
Страница 13: ...eaning must be carried out by specialists electricians The personnel must ensure that for the duration of this work the unit and the cabinet are disconnected from the electrical supply and protected a...