background image

Version Nr. 1-1 - 05.03.2020

Doc. Nr. 9951650033

3 / 14

Disregarding the instruction manual
Operating error
Inappropriate work on or with the unit
The use of non-specified spare parts and accessories
Unauthorised modifications or changes to the unit by the user or his personnel

The supplier is only liable for errors and omissions as outlined in the guarantee conditions contained in the main
contractual agreement. Claims for damages on any grounds are excluded.

3. Safety instructions

Upon delivery the unit is already meeting current technical standards and can therefore be safely taken into
operation. Only authorised personnel is allowed to work on the unit. Unauthorised personnel must be prohibited
from working on the unit. Operating personnel must inform their superiors immediately of any malfunction of
the unit. 
Please note that before starting to work on or with the unit, a procedure must be carried out inside the cabinet
on which the unit is to be mounted.
Before commencing work inside the cabinet, the control cabinet manufacturer's instruction must be read with
regards to:

Safety instructions.
Instructions on taking the cabinet out of operation.
Instructions on the prevention of unauthorised cabinet reconnection.

The electric equipment meets the valid safety regulations. One can find dangerous voltages (above 50 V AC or
above 100 V DC)

Behind the control cabinet doors.
On the power supply in the unit housing.

The unit has to be operated according to the type plate and the wiring diagram, and must be protected
externally from overloading and electrical faults via suitable protective devices.

Danger through incorrect work on the unit
The unit can only be installed and maintained by technical competent and qualified
personnel, using only supplied material according to the supplied instructions.

Danger from electrical voltage
Only specialised personnel are allowed to maintain and clean the unit. The personnel must
ensure that for the duration of the maintenance and cleaning, the unit is disconnected from
the electrical supply.

Attention
Damage to the unit through the use of inappropriate cleaning materials. Please do not use
aggressive cleaning material.
 

Instruction
Damage to the environment through unauthorised disposal. All spare parts and associated
material must be disposed according to the environmental laws.

Содержание 3BHB022684R0101

Страница 1: ...3 Safety instructions 3 4 Technical functions 4 5 Technical data 4 6 Performance Graph 5 7 Mounting 6 8 Mounting Principle 7 9 Dimensions H x W x D 8 10 Electrical connection 9 11 Wiring diagram 10 12...

Страница 2: ...e instruction manual must be adhered to General danger Indicates compulsory safety regulations which are not covered by a speci c pictogram such as one of the following High electric voltage Indicates...

Страница 3: ...d with regards to Safety instructions Instructions on taking the cabinet out of operation Instructions on the prevention of unauthorised cabinet reconnection The electric equipment meets the valid saf...

Страница 4: ...emperature sensitive components The characteristic graph shown in the section Performance graph applies to external ambient air as the coolant In air to air heat exchangers the internal temperature of...

Страница 5: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 5 14 6 Performance Graph T Temperature di erence between ambient and internal temperature P heat exchanger performance...

Страница 6: ...te thoroughness to ensure that the unit works perfectly Transport damage check On delivery the carton containing the unit must be examined for signs of transport damage Any transport damage to the car...

Страница 7: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 7 14 8 Mounting Principle...

Страница 8: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 8 14 9 Dimensions H x W x D...

Страница 9: ...er technical data Connecting the alarm and door contact interface To avoid unnecessary run time the heat exchanger can be switched on and o through the door contact There is also an alarm contact that...

Страница 10: ...ommon 3 Pink NC 4 not connected Connector J3 J5 J7 J9 Molex mini t jr 2 pole capacitor 1 Brown 2 Blue Connector J11 Molex KK 2 pole Door contact 1 Brown ON 2 Grey ON Connector J18 19 Molex mini t jr 2...

Страница 11: ...31 5 A T LED D3 5 7 9 Fuse OK LED D23 25 27 29 Fan OK green LED D24 26 28 30 Fan FAULT red Test buttons 0 10 sec All fans ON 10 20 sec Fan 1 ON fans 2 3 4 OFF 20 30 sec Fans 1 2 ON Fans 3 4 OFF 30 40...

Страница 12: ...Version Nr 1 1 05 03 2020 Doc Nr 9951650033 12 14...

Страница 13: ...eaning must be carried out by specialists electricians The personnel must ensure that for the duration of this work the unit and the cabinet are disconnected from the electrical supply and protected a...

Страница 14: ...be maintained at all points between the unit and the external packing The unit must be rmly xed in the packing The unit must be protected su ciently by shock absorbing padding hard foam corner pieces...

Отзывы: