Product Description
Front View EPM Plus 5G
Front View EPM Plus 5G
The Solis EPM 5G is a device that allows you to adjust export values to satisfy local network
regulatory requirements.
General Notes
•
Do not place
communication cables with DC and AC cables in the same conduits or
trunking as this may influence the normal communications.
•
Ensure that the communication
wires between the inverter and EPM are properly
connected as
in the manual. (refer to system wiring diagram)
•
The EPM should always be connected to the first inverter on the RS485 bus if multiple
units are installed and the other inverters must be daisy chained.
•
The secondary current for the CT should be 5A and recommended class 0.5CT for
higher accuracy on the measured values.
•
The load must be switched off before disconnecting CT as this will open circuit the
secondary of the CT and may cause damage to CT, EPM or injury.
•
Date & Time setting
must be the same on the EPM and the Inverters.