15
Ver. 1.0
SHIN HWA Eng.Co.,Ltd.
CONTROL ACTUATOR
CA01H~CA120H
3 Maintenance
3-1 Troubleshooting
Symptom
Expected Cause
How To Repair
Note
The motor
does not
work.
Power is not supplied.
Supply power.
In case of three phase,
check R, S, and T.
The position control
switch operates.
Reset to fit the scale
plate.
The torque switch
operates.
Remove the cause for
overload.
Reset the switch.
(Never randomly set.)
The overload relay
operates.
Remove the cause for
overload.
Reset the set value.
(Never randomly set.)
The fuse is broken.
Replace the fuse.
In case of three phase
The condenser is
damaged.
Replace the
condenser.
In case of single phase
The brake does not
work.
Replace the brake.
The motor
does not stop
with the
position
control
switch.
The motor makes a
reverse rotation.
Connection is made
with two lines among
three lines changed.
It is in case of three
phase, and it does not
apply to the standard.
The position control
switch is changed.
The position control
switches (LS1, LS2)
are used by being
changed.
It does not apply to the
standard.
The switch setting is
defective.
Reset.
The switch is defective. Replace the switch.
When the
torque switch
operates, the
motor does
not stop.
The motor makes a
reverse rotation.
Connection is made
with two lines among
three lines changed.
It is in case of three
phase, and it does not
apply to the standard.
The torque switch is
changed.
The position control
switches (LSR, LSF)
are used by being
changed.
The switch is defective. Replace the switch.