SEQUENCER CONTROLLER
WITH OR WITHOUT
DIFFERENTIAL PRESSURE MEASUREMENT
Technical Notice
FI 72.0308.0316E
Page 5 sur 15
- 5 -Page 5 sur 15
- 5 - - 5 -
- 5 -
- 5 -
ADJUSTMENTS AND RUNNING:
The various parameters are set as follows:
- Press the « SELECT » key until the yellow led « menu » lights up opposite the parameter to be set and operate
the keys « + » and « - » to obtain the desired value.
- Then return to the “CYCLE” position (or “pressure reading” position if it’s equipped with the DP) using the
« SELECT » key. Each parameter is recorded in a memory by moving to the following step or on automatic return
to the “CYCLE” position (or « pressure reading » position if it’s equipped with the DP).
Comment
:
- The return to the “CYCLE” position (or “pressure reading” position if it’s equipped with the DP) is automatic
after 30 seconds (unless in « cycle » position).
- Each parameter can be viewed at any time during the operating of the device.
The visualisations 1 to 7 and 13 are only used if the sequencer is equipped with the DP.
1) DP measurement view:
Display the DP measurement.
If there is an error, alternating display of the type of fault.
If pressed, display of nxx with xx = EV will be actuated at the next blast
If cleaning is in running, rapid flashing of the led of the menu opposite to the corresponding time.
If manual operation is in course or fan stoppage cycles are in course, the menu led opposite the fan/manu
flashes rapidly.