![SEFRAM BK Precision DAS30 Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/sefram/bk-precision-das30/bk-precision-das30_user-manual_1233326011.webp)
11
Getting Started
You turn on the recorder by pressing the button at the top of the device.
When the device is on, the ON/OFF button is lit blue.
After launching the software, the recorder displays a homepage that specifies the hardware version, then switches auto-
matically to the «
Direct display
» mode (oscilloscope).
You can display this homepage any time in the main menu by pressing
.
To turn off the device, you only have to press the ON/OFF button twice.
If the device does not stop correctly, you must press the power button for 5 seconds and the recorder will shut off; in this
case, the instrument configuration will not be saved.
2.1 Measurement Types
Voltage
The voltage is measured between the red and black terminals of the inputs with wires and male
security pin plugs (according to CEI 1010).
Thermocouple Temp
The voltage resulting from thermocouple effect must be measured between the red and black ter-
minals of the relevant input. To provide right measure values, connect the two ends of the ther-
mocouple cord directly onto the quick fastening socket. Plug the two pin plugs onto the selected
input with respect of the polarity. (Do not use welding male pin plugs: the welding would alter
the thermocouple effect.)
Platinum RTD
The Pt100 probe must be connected on the « I+ » and « I- » terminals.
The voltage from the Pt100 must be measured between the « + » and « -» terminals with one
of the two following mountings: 2, 3 or 4 wires. The 3 or 4-wire mountings make the measure-
ment independent from the resistance of the line.
Current
You can make current measurements by
shunt
between the red and black terminals of the rel-
evant input.
In this case, select the "
current
" type among the parameters of the relevant channel. Connect
the measurement wires to the terminals of the shunt.
The results are directly displayed in Amperes or milliamperes according to the caliber of the se-
lected channel.
Logic
Using the Logic input (25 pin connector) digital signals can included in the recording or used as
triggers. The logic connector also includes pins that can be used as output signals (alarms) for
other equipment. Up to 16 signals are available for recording and triggering and 4 signals for alarm
outputs.
2.2 Powering the Recorder
Each recorder includes an internal rechargeable Lithium-Ion battery. The recorder is powered and charged by a 15 V 4
A charger. The charger included with the recorder is powered by 100-240 VAC at 50-60 Hz. The recorder runs with or
without the power supply connected and provides up to 8 hours of power when running on battery. When the power
supply is connected a green LED lights beside the 25-pin logic input connector.
To turn on the recorder, press the button labeled “ON/OFF” located on the top surface of the recorder. When on, the
ring around the button lights up blue. Battery charge state is shown on the front screen.
To turn off the recorder press the power button. A window will appear on-screen prompting for confirmation; press the
green “Check Mark” to shut down the recorder. If the red “X” is pressed or if the green “check mark” is not pressed
within 10 seconds, the recorder will not turn off.
2.3 Connections
Содержание BK Precision DAS30
Страница 9: ...9 17 Specifications 81 18 LIMITED TWO YEAR WARRANTY 82 19 Service Information 83 ...
Страница 22: ...22 Figure 4 4 Figure 4 5 You get access to ...
Страница 63: ...63 Figure 11 10 ...
Страница 67: ...67 Figure 12 5 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...
Страница 74: ...74 Figure 14 3 ...