29
Ausgabe
issue
D / 15.03.2010
Dokument
document
OM.MAI.51e
Blatt
sheet
1 (5)
9
Dismantling / Reassembly
9.1
Pump Dismantling / Reassembly
Range: BCSB
Size: 025-12 to 1-6L, 1-6 to 75-6LT
9.1.1 Prepare the pump for dismantling
9.1.2 Dismantling
9.1.2.1 Pressure branch (700) - dismantling
DANGER
Dangerous voltage.
Death or serious injury can occur.
Note safety regulations.
Disconnect pump from all sources of energy.
Secure electrical connections against restarting.
Empty pipelines.
Allow pipelines to cool down.
Remove pipeline connections (suction
side/pressure side).
Note decommissioning (chapter 6._).
WARNING
Tilting or falling pump.
Death or serious injury can result.
Attach lantern (200) to secure the pump.
200
Prop up stator (601) with support (S).
700
S
602
720
607 719
601