Release Version 1.0

 

 

Precautionary and Safety Guidelines

 

The content of this guideline is intended to protect the safety of the user and prevent damage to property. 
Please read these operating instructions carefully and use the device as intended. 

Warning 

(Failure to adhere to any of the following guidelines could result in 

serious injury or death for someone.)

 

■  Make sure to install the product after unplugging the power cord. Also, do not use many 
power plugs at the same time. 

- Doing so could result in abnormal heat, fire, and electric shock. 

■  Do not leave the device in a place where water will fall or splash. Also, don't put anything 
with water on it, such as a flower vase. 

- If liquid gets inside the device, it may cause malfunction or fire 

■  Do not bend the power cord with excessive force. Make sure that the power cord is not 
crushed by heavy objects. 

- It can cause fire. 

■  Do not open the cover arbitrarily as there is a high voltage part in this device. Never 
disassemble, repair, or modify it. 

- Improper work can lead to fire, electric shock and injuries. 

■  Do not install this product in a location with high humidity, dust, or soot. 

- Electric shock and fire may result. 

■  Do not pull on the section of the power cord and do not pull out the power plug with wet 
hands. If the power cord is loose, do not plug it in. 

- There is a risk of fire and electric shock. 

■  Always keep the location clean and dust-free during or after the installation of the device. 
When cleaning the device, wipe it with a dry cloth and do not use water, thinner, or organic 
solvents. 

- Doing so could result in malfunction or fire 

■  Store the device in a cool place out of direct sunlight. Keep it at a reasonable temperature 
and avoid heating devices such as candles or heaters. Also, keep the equipment or tools away 
from places where people go in and out. 

- There is a risk of damage to the surface of the device and the risk of failure, electric shock or fire. 

■  Be aware of potential hazards in the workplace, such as wet floor, ungrounded power 
extension cords, old power cords and lack of protective earth. If you have any problems, contact 
your seller or specialist. 

- Doing so could result in fire or electric shock. 

■  The input voltage required to operate this equipment must have a voltage fluctuation range 
within 10% of the specified voltage, and the outlet must be grounded. Also, do not use 
electrical appliances such as hair dryers, irons, and refrigerators with the outlet to which the 
power plug is connected. 

- Doing so could result in abnormal heat, fire, or electric shock. 

■  During thunderstorms or lightning strikes, pay attention to safety and pull out the power 
plug. 

Содержание SC-IPC3001G

Страница 1: ...Release Version 1 0 1 channel IP 1Giga Uplink Transmission System SC IPC3001G User Guide SC IPR3001G SC IPT3001G ...

Страница 2: ...and do not pull out the power plug with wet hands If the power cord is loose do not plug it in There is a risk of fire and electric shock Always keep the location clean and dust free during or after the installation of the device When cleaning the device wipe it with a dry cloth and do not use water thinner or organic solvents Doing so could result in malfunction or fire Store the device in a cool...

Страница 3: ...s rainwater dew fog from entering the inside of the device via the cable lay the cable in a U shape when connecting If you notice unusual noises or smells pull out the power plug immediately and contact the dealer or the service centre There is a risk of fire and electric shock If you have any problems or questions other than those listed above see the troubleshooting guide at the end If you need ...

Страница 4: ...Features 1 Gbit s bandwidth support between transmitter receiver Supports up to 780 Mbit s 370 Mbit s full duplex based on RG 59 The maximum transmission distance is 900 m based on RG 59 see 5 1 Transmission Distance Table Power supply for IP PoE camera available PoE type B support Safe power transmission with automatic line diagnosis function PoE ON OFF can be set on the transmitter supports both...

Страница 5: ...P camera connector Green LED Ethernet Activity LED Green Blink Orange LED Ethernet Link LED Giga Link Orange On When connecting with 100Mbps products the Orange LED may be blinking CAM PoE PoE power supply setting switch When connecting a PoE IP camera set the CAMERA PoE switch to ON When the product is shipped the PoE switch is set to PoE ON If you connect an IP camera that does not support PoE s...

Страница 6: ...nect the transmitter adapter during pairing LED Status Indicator Location Name LED Status indicator Function Top Link Off No Link Red Poor Link Green Blink Link OK Act OK Bottom PWR Off No power input Green On Successful power connection Red Blink Camera side power supply error short circuit disconnection overcurrent Orange Blink Pairing status NVR Side NVR or PoE hub connection port Green LED Eth...

Страница 7: ...alf Duplex PoE output Bandwidth TCP IP Full Duplex PoE output RG 58 200 m 743 Mbps 21W 375 Mbps 30W 400 m 538 Mbps 11 8W 270 Mbps 23W 600 m 270 Mbps 7 6W 137 Mbps 15 9W 800 m 154 Mbps 5 4W 78 Mbps 12W RG 59 200 m 778 Mbps 19W 350 Mbps 30W 400 m 608 Mbps 6W 305 Mbps 13W 600 m 377 Mbps 4W 200 Mbps 9W 800 m 280 Mbps 3W 140 Mbps 7W 900 m 230 Mbps 2W 110 Mbps 5 8W The camera is supplied with power usin...

Страница 8: ...h one adapter is not recommended It is not recommended when the products are in contact or connected to each other When installing the product press the function button for 2 to 5 seconds to pair Remove the transmitter power supply during pairing Pairing function does not work if the transmitter power supply is connected Switch off PoE on the transmitter when using the camera power supply unit In ...

Страница 9: ... 10 100 1000 Mode B T568A T568B 1 White Green White and orange TxRx A 2 Green Orange TxRx A 3 White Orange White Green TxRx B 4 Blue Blue TxRx C DC 5 White Blue White Blue TxRx C DC 6 Orange Green TxRx B 7 White Brown White Brown TxRx D DC 8 Brown Brown TxRx D DC ...

Страница 10: ...tion make sure that the PoE switch on the transmitter is set to ON PoE doesn t funtion Verify that the network cable pins are arranged correctly Check if the NETWORK CABLE transmission distance is within 100m Based on CAT 5e When using the PoE function make sure that the PoE switch on the transmitter is set to ON Make sure your IP camera is PoE capable Network connection is unstable Verify that th...

Страница 11: ...n TX 3Pin RX 4Pin PWR 5Pin PWR 6Pin RX 7Pin PWR 8Pin PWR LED Status Indicator PWR Green On Successful connection Orange Blink Pairing status Red Blink Camera side power supply error short circuit disconnection overcurrent Red On PoE Switch off Link Off No Link Red On Poor Link Green Blink Link OK Act OK PoE Switch On PoE power supply to camera Off PoE function is off Operating Temperature Operatin...

Страница 12: ...TTER SIDE BNC F 75Ω NVR SIDE RJ 45 TIA EIA568B Type POWER PORT DC Jack RJ 45 Connector 1Pin TX 2Pin TX 3Pin RX 4Pin PWR 5Pin PWR 6Pin RX 7Pin PWR 8Pin PWR LED status indication PWR Green On Successful connection Orange Blink Pairing Red Blink Transmitter side power supply error short circuit disconnection overcurrent Link Off No Link Red On Poor Link Green Blink Link OK Act OK Operating Temperatur...

Страница 13: ...r service according to the warranty certificate We charge you with the fee of parts and service despite of free warranty service period Any breakage made without care such as Breakdown due to natural disasters lightning fire flood tsunami etc When disassembled or repaired by the user When connecting power other than rated power When you want to reassemble for full system or replace parts within wa...

Страница 14: ...3 SeeEyes Co Ltd 503 509 511 512 Sunil Technopia 555 Dunchon daero Jungwon gu Seongnam City Gyeonggi Province Korea Zip Code 13215 TEL 82 0 31 730 5834 FAX 82 0 31 777 3512 EMAIL overseas sscctv com http www sscctv com eng ...