V2.0 7-31-12
23
Adjusts the L/R scan speed. The speed range is adjustable from 1 to 64.
)
Procedure:
1. Call preset point 95 to enter the main menu.
2. Move cursor to choose
[PANTILT SETTING]
choose
[AUTOSCAN SETUP]
and press
[OPEN]
to confirm the selection to enter scan function set item.
3. Under
[AUTOSCAN SETUP]
choose
[DEFAULT SPEED]
item and press
[OPEN]
to confirm
the selection to enter default scan speed set item.
4. Up/down P/T to change speed value, the speed can be set from 1 to 64.
5. Press
the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit directly without saving.
HOME ACTION
If the camera does not receive any commands for a set time, it can perform a specific action set on
this screen. The time can be set from 5 to 255 and the action to perform can be to call any of the 200
presets, 4 sequences, 4 scans or 4 patterns.
PANTILT SETTING HOME ACTION
•
HOME TIME
)
Procedure:
1. Call preset point 95 to enter the main menu.
2. Use the Up/down cursor to choose
[PANTILT SETTING]
choose
[HOME ACTION]
item and
press
[OPEN]
to confirm the selection.
3. Under
[HOME ACTION]
choose
[HOME TIME]
item and press
[OPEN]
to confirm the
selection and enter into the home time setting item.
4. Use Up/down P/T to modify the delay time, from 5 to 255 seconds.
5. Press
the
[OPEN]
key to save and exit. Press the
[CLOSE]
key to exit directly without saving.
•
HOME ACTION
)
Procedure:
6. Call preset point 95 to enter the main menu.
7. Use the Up/down cursor to choose
[PANTILT SETTING]
choose
[HOME ACTION]
item and
press
[OPEN]
to confirm the selection.
8. Under
[HOME ACTION]
choose
[HOME ACTION]
item and press
[OPEN]
to confirm the
selection and set the home action item.
9. Use Up/down P/T to modify the home action. The action to perform can be to call any of the
200 presets, 4 sequences, 4 scans or 4 patterns.
【PANTILT SETTING】
【PRESETS SETUP】
【SEQUENCE SETUP
】
【PRESETS SETUP】
【AUTOSCAN SETUP
】
→ HOME TIME : 255