background image

PACKAGE CONTENTS 

 

This package contains: 
 

One ST-PTZIR480-22X high-speed intelligent dome color camera. 
One mounting bracket. 
One 24VAC 3A power supply. 
One installation manual. 

 

 

PRODUCT DESCRIPTION 

 

The ST-PTZIR480-22X is a professional grade infrared intelligent dome color camera with pan, tilt and zoom (PTZ) 
capability and 480TVL resolution. The camera’s non-volatile digital memory allows the saving of all settings. Its 
200 preset positions provide versatility for cruise routes and tour functions. The ST-PTZIR480-22X’s mechanical 
design permits continuous horizontal 360

°

 rotation and 90

°

 vertical flip. Temperature management is built-in. 

 
 

Functions and Features 

Non-volatile design ensures data will not be lost if power fails. 
Recovery function allows the camera to continue previous functions after power is restored. 
Support for 200 presets and 4 preset tours, each containing up to 32 presets. 
4 patterns, each can be recorded for 1000 discrete PTZ controller moves. 
Support for 4-auto scans. 
Soft and hard ID settings can be edited on the DIP switch or via the OSD menu. 
Integrated multi-protocol control: PELCO“P”, PELCO“D”. 
2 ch alarm input; 2 ch alarm relay output.  
Proportional zoom lens; P/T speed will decrease in proportion with depth of zoom.

 

Can be installed indoors or outdoors. 
Horizontal pan speed 0.5º-82º/s. 
Vertical tilt speed 0.5º-30º/s. 
360º continuously horizontal rotation. 
Complies with IP 66/CE standard. 
Built-in surge protection circuitry. 
Auto focus, manual priority. 
Auto iris. 
Auto shift from Color to B/W. 
Built-in OSD makes it easy to configure all settings of the camera. 
Built-in display for the internal dome temperature, preset status and compass direction. 

      330ft IR distance for long-range surveillance. 

 

 

 

 

 

 

Содержание ST-PTZIR480-22X

Страница 1: ...INSTALLATION MANUAL ST PTZIR480 22X High Speed Intelligent Dome IR PTZ Color Camera Copyright North American Cable Equipment Inc ...

Страница 2: ...era to continue previous functions after power is restored Support for 200 presets and 4 preset tours each containing up to 32 presets 4 patterns each can be recorded for 1000 discrete PTZ controller moves Support for 4 auto scans Soft and hard ID settings can be edited on the DIP switch or via the OSD menu Integrated multi protocol control PELCO P PELCO D 2 ch alarm input 2 ch alarm relay output ...

Страница 3: ...ion Display Yes 14 Pan Tilt Position Display Yes 15 MAX IR Distance 330ft 19 Patterns 4 programmable pan tilt zoom and each tour is 120 seconds 20 Sequences Tours 4 programmable dwell time speed preset point 21 Protocol Pelco D Pelco P selectable 22 Auto Scan With programmable variable speed 23 High Efficient 3 Dimension Scan Yes 24 Long Focus Speed Limited Yes 26 Home Position Yes 27 Camera Menu ...

Страница 4: ...Dimensions Wall Mount Dimension Picture 2 6 7 5 5 6 10 1 8 4 1 8 6 4 1 8 6 1 8 3 5 ...

Страница 5: ...ssembled factory tested Ensure that all accessories are removed from the container before discarding packing materials a Use the mounting arm as a template to mark the holes for your mounting hardware This symbol is intended to alert the user to the presence of important operating and maintenance servicing instructions This symbol is intended to alert the user to the presence of uninsulated danger...

Страница 6: ... towards the sun or strong light c Do not install the camera in an environment where the temperature is above 122 F d Do not install the camera near a magnetic field or a high power motor e Do not mount the camera near a radiator or heater f The installation site and material must fully support the weight of the product g Only use a dry cloth to clean the camera If there is dirt that is difficult ...

Страница 7: ...4 CAMERA SETUP BAUD RATE PROTOCOL SETUP DIP Switch Settings Baud rate Setting SW2 B7 B8 Protocol Setting SW2 B1 B2 ...

Страница 8: ...DOME ADDRESS SETUP System Setup DIP Switch SW1 ON 1 OFF 0 ...

Страница 9: ...V2 0 7 31 12 9 ...

Страница 10: ... limit point for L R scan Call PRESET 93 Set Right limit point for L R scan Call PRESET 99 Run Left right scan NOTE If Left limit point and Right limit point are set to the same position calling preset 99 will execute a 360 scan Call PRESET 33 Swing 180 Call PRESET 34 Return to Zero point The on screen menu provides access to all camera functions through the use of a standard RS485 connection and ...

Страница 11: ...F ZOOM POSITION OFF DIRECTION INDICATOR OFF ENVIRONMNT INDICATORS OFF PAN TILT SETTING PRESETS SETUP SEQUENCE SETUP PATTERN SETUP AUTOSCAN SETUP HOME ACTION LENS PARAMETER EXPOSURE MODE WHITE BALANCE BACKLIGHT MODE DOME ID TITLE LANGUAGE SELECT CHANGE PASSWORD FACTORY DEFAULT SYSTEM RESTART SYSTEM INFOMATION INPUT CHANNEL 001 ALARM ACTION DISARM INPUT MODE NO ALARM LINKAGE OFF RELAY OUTPUT OFF RES...

Страница 12: ...ng menu 4 Under SYSTEM SETTING choose DOME ID and press OPEN to confirm 5 Using the up down and left right PTZ controls enter the 12 character serial number shown at the top of the menu and press OPEN to move to the next menu 6 Enter the new dome ID and press OPEN The menu will show the new dome ID and prompt to press OPEN to accept 7 Set your PTZ controller to the dome s new address and press OPE...

Страница 13: ...first Input the old password and press the OPEN key Input New Password will be shown on the screen Input the new password then re enter it once more to confirm Password Modification Succeed will be shown on the screen 7 CAUTION For security reasons there is no way for users to bypass or reset the password settings If a password is entered incorrectly or forgotten it will be impossible to access th...

Страница 14: ...PEN to save and exit this item setting Press CLOSE to exit immediately without saving z DIGITAL ZOOM SETTING Procedure 1 Call preset 95 to enter the main menu 2 Use the up down PTZ controls to choose CAMERA PARAMETERS and press OPEN to confirm the selection then enter the LENS PARAMETER menu 3 Under LENS PARAMETER choose DIGITAL ZOOM and press OPEN to confirm the selection and enter electronic zoo...

Страница 15: ...enters the exposure sub menu set 4 In the Exposure Mode menu choose the EXPOSURE MODE line item and press OPEN to confirm the selection and enter the exposure mode selection setting EXPOSURE MODE The 5 available choices are 1 IRIS 2 SHUTTER 3 BRIGHT 4 USER and 5 AUTO When the exposure mode is set to AUTO all exposure settings are handled by the camera automatically This is the recommended setting ...

Страница 16: ...e red gain and blue gain settings can also be set manually CAMERA PARAMETERS WHITE BALANCE WHITE BALANCE SETTING Procedure 1 Call preset 95 to enter the main menu 2 Choose CAMERA PARAMETERS and press OPEN to confirm the selection 3 Choose WHITE BALANCE and press OPEN to confirm the selection and enter the white balance menu settings 4 The WHITE BALANCE parameters can be set as bellow AUTO This is ...

Страница 17: ...nd upward 90 vertically after the tilt is positioned straight down This allows the camera to operate as if it had 180 vertical tilt capability Procedure 1 Call preset point 95 to enter the main menu 2 Under PANTILT SETTING choose the PANTILT SETTING sub menu and press OPEN to confirm the selection 3 Under PANTILT SETTING choose AUTO FLIP and press OPEN to confirm the selection LENS PARAMETER EXPOS...

Страница 18: ... confirm the selection 4 Up down P T to change the setting 5 Press the OPEN key to save and exit Press the CLOSE key to exit directly without saving SPEED PROPORTIONAL This function causes the speed at which the camera pans to decrease proportionately with the amount of zoom applied When the camera is zoomed out wide it will pan at full speed When the camera is zoomed in far the camera will pan sl...

Страница 19: ...NG menu press OPEN to confirm the selection and enter pan parameter set 3 Under PANTILT SETTING choose SET NORTH DIRECTION menu and press OPEN to confirm the selection and prepare to aim the camera 4 Use the PTZ controller to aim the camera lens to the North 5 Press the OPEN key to save and exit Press the CLOSE key to exit directly without saving GOTO ZERO POSITON This function causes the camera t...

Страница 20: ... preset name 3 Press the OPEN key to save and exit Press the CLOSE key to exit directly without saving z SET NEW PRESET Procedure 1 Call preset point 95 to enter the main menu 2 Up Down cursor to choose PANTILT SETTING press OPEN to confirm the selection and enter pan set menu 3 Under PANTILT SETTING choose PANTILT SETTING menu press OPEN to confirm the selection 4 Under PANTILT SETTING choose SET...

Страница 21: ...hanged 4 Use the Up down and L R PTZ controls to assign a preset for each step of the sequence If a preset is not assigned to a step the sequence will skip that step 4 Once all steps are set press the OPEN key to save and exit Press the CLOSE key to exit directly without saving Note Each group of parameters has two numbers the first represents the preset point number and the second is the dwell ti...

Страница 22: ...r the main menu 2 Use the Up Down cursor to choose PANTILT SETTING and press OPEN to confirm the selection and enter pan set menu 3 Under PANTILT SETTING choose AUTOSCAN SETUP and press OPEN to confirm the selection 4 Under AUTOSCAN SETUP press AUTOSCAN NUMBER and choose 1 of the 4 autoscan routes to be edited Use the Up down P T to choose a scan route 5 Press the OPEN key to save and exit Press t...

Страница 23: ...TILT SETTING HOME ACTION HOME TIME Procedure 1 Call preset point 95 to enter the main menu 2 Use the Up down cursor to choose PANTILT SETTING choose HOME ACTION item and press OPEN to confirm the selection 3 Under HOME ACTION choose HOME TIME item and press OPEN to confirm the selection and enter into the home time setting item 4 Use Up down P T to modify the delay time from 5 to 255 seconds 5 Pre...

Страница 24: ...ayed on the OSD for that amount of time then it will stop being displayed and not be displayed again until a PTZ command is received from a controller 4 Press the OPEN key to save and exit Press the CLOSE key to exit directly without saving Note Preset Title Zoom Position Direction Indicator and Environmental Indicators are all set using the same method as Dome Title GLOBAL SETTING 1 All of the OS...

Страница 25: ...ss OPEN to confirm the selection 4 Use the Left right P T controls to choose arming or disarming the alarm function 5 Press the OPEN key to save and exit Press the CLOSE key to exit directly without saving INPUT MODE Setting Methods NC Normally Closed The normal alarm off state of the input is a closed circuit Opening the circuit triggers the alarm NO Normally Open The normal alarm off state of th...

Страница 26: ...or use with the alarm outputs can be configured for N O operation Procedure 1 Call preset point 95 to enter the main menu 2 Use the Up Down cursor to choose ALARMS SETUP and press OPEN to confirm the selection and enter alarm set items 3 Under ALARMS SETUP choose one of the 2 alarm inputs to link to a relay AUX output 4 Select RELAY OUTPUT and press OPEN to confirm the selection 5 Use the Up Down ...

Страница 27: ...een the camera and any fluorescent lamps in the vicinity d The picture appears smeared i The power supply voltage level may be unstable Try another power supply ii Ensure the cables are correctly connected and of the right impedance e Other interference may require the use of a SecurityTronix ground loop isolation filter f Power is on but the controller does not work i Check to make sure the DIP s...

Отзывы: