Continuation of table 4.1
1
2
3
2. The sensor
generates nuisance
alarms periodically
1. Moving objects in the
detection zone.
2. Animals movement in
the sector.
3. Too high sensitivity.
4. Influence of the
adjacent sensor with the
same frequency letter.
Inspect the sector and remove
interference factors
Align the sensor according to
items 2.3.7.2-2.3.7.5.
Install the sensors with different
frequency letters.
Align the sensor according to
items 2.3.7.2-2.3.7.5.
Replace the transceiver unit.
3. The sensor does
not generate alarms
when a person
crosses the
detection zone.
1. Too low sensitivity.
2. The transceiver unit is
out of order.
5
Storage
5.1
Store the sensors in factory package on racks in the warehouse.
5.2
Use heated warehouse with the temperature inside from plus 5º C to plus 40º C,
humidity up to 80 %.
5.3
No vapour of acid, alkaline and other chemically active substances causing the
corrosion are allowed in the warehouse.
5.4
Strictly follow the manipulation marks on the package during storage.
5.5
Mean shelf life time in the factory package at the temperature from plus 5º C to plus
40º C and the humidity 95 % at the temperature of 35º C is not less than 3 years.
Содержание ZEBRA-24.60
Страница 1: ...SECURITY SENSOR ZEBRA 24 60 User manual CE Certificate of compliance No PS 19 015 ...
Страница 33: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 33 October 17 2019 Figure 2 8 Figure 2 9 ...
Страница 34: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 34 October 17 2019 Figure 2 10 Figure 2 11 ...
Страница 40: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 40 October 17 2019 Figure 2 18 ...