2.3.6
Connections of the sensor
2.3.6.1
Connect power, signal and remote control circuits in accordance with the project for
the alarm system. The transceiver unit is to connect with its own cable. The purpose
of the conductor is determined by its colour. Colour and purpose of wires shown in
table 2.1.
ATTENTION! IT IS STRICTLY PROHIBITED TO GROUND SENSOR`S
CIRCUITS DIRECTLY. IT IS NECESSARY TO USE A LIGHTNING GUARD
UNIT (LGU).
Table 2.1 – Purpose of wires
Colour of wires
Purpose
Note
White
Supply plus (+)
Brown
Supply minus (-)
Yellow
Relay contacts (NC)
Pink
Purple
Tamper circuit
(TAMPER)
Black
Green
Remote control (RC)
Blue
RS-485 «В»
Red
RS-485 «A»
Grey
Bluetooth activation
For sensor