![SECURITY SENSOR ZEBRA-24.60 Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/security-sensor/zebra-24-60/zebra-24-60_user-manual_1232215018.webp)
ZEBRA-24.60
ZEBRA-24.60 User Manual
18
October 17, 2019
2
Intended use
2.1
Use limits
2.1.1
The sensors can be used only, if conditions of item 1.1.5 of the present user manual
are met.
2.1.2
Site requirements should meet requirements of items 1.2.2.1, 1.2.2.2.
2.1.3
The input signal level depends on height and weight of a person, his speed of
movement, point of crossing the area and relief.
2.1.4
The signal at the input of the sensor may be changed influenced by precipitation,
small animals, electromagnetic interference, trees and wings of a gate entering the
detection zone, with amplitude comparable to the human intrusion.
2.1.5
The following factors can affect the input signal: extensive buildings or objects
(fences, walls etc.) near the detection zone, uneven terrain, snow or vegetation on the
area. If such factors take place, due to reflections and interferences the detection zone
is distorted.
2.1.6
On objects with the increased lightning statics, it is necessary to use lightning units.
The lightning units should be used when the length of connecting lines exceeds 300
m.
Содержание ZEBRA-24.60
Страница 1: ...SECURITY SENSOR ZEBRA 24 60 User manual CE Certificate of compliance No PS 19 015 ...
Страница 33: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 33 October 17 2019 Figure 2 8 Figure 2 9 ...
Страница 34: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 34 October 17 2019 Figure 2 10 Figure 2 11 ...
Страница 40: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 40 October 17 2019 Figure 2 18 ...