3.3.3
Checking of the sensors appearance
3.3.3.1
Check the integrity of the transceiver unit, pay attention to the absence of dents,
corrosion, damage of coating, cracks. In case of presence of corrosion signs
remove if with a rag with kerosene and put an anti-corrosion agent.
3.3.3.2
Check the transceiver unit for the absence of dust, dirt, snow and ice from the
side of transmitting and receiving and clean them if necessary.
3.3.3.3
Check the tightening of fixing parts fixing the sensor units to the pole or
protected surface; tighten the fixing parts if necessary.
3.3.3.4
Check the state of connection cables from the sensor unit to the junction box.
3.3.4
Checking of the protected sector state
3.3.4.1
Check the protected sector for the absence of foreign objects causing false
alarms.
3.3.4.2
Check the height of grass cover during seasonal works. In case grass exceeds the
allowed height (see item. 1.2.2.1), remove it.
3.3.4.3
The changing of height of snow cover on the protected site may reduce the input
signal on the transceiver causing false alarms. Remove the snow or change the
height of installation of the transceiver on the pole.
After changing the height of installation of the transceiver, configure the
triggering threshold according to the procedures given in the present User
Manual.
Содержание ZEBRA-24.60
Страница 1: ...SECURITY SENSOR ZEBRA 24 60 User manual CE Certificate of compliance No PS 19 015 ...
Страница 33: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 33 October 17 2019 Figure 2 8 Figure 2 9 ...
Страница 34: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 34 October 17 2019 Figure 2 10 Figure 2 11 ...
Страница 40: ...ZEBRA 24 60 ZEBRA 24 60 User Manual 40 October 17 2019 Figure 2 18 ...