XRSuper6 Introduction
3
Central Station Monitoring
Your system can also be programmed to automatically send alarm,
trouble, and arming and disarming reports to a central station.
Operators at the central station can then dispatch the
appropriate authorities or contact you with event information.
Status
There are two types of status information available:
Status
List
and
Armed Status
.
Status List
The keypad Status List displays any alarm or trouble conditions
on a zone and any trouble condition that occurs with the AC
power or battery power. If your system contains any Panic zones,
these are
not
displayed on the keypad for security reasons.
If an alarm occurs on a non-fire, 24-hour zone or a system monitor,
it remains in the Status List until it restores. If one or more
armed burglary zones trips, the last one to trip remains in the
Status List. The burglary zone alarm remains in the Status List for
several minutes or until it is cleared by disarming the system.
Zone Status
To display the status of a particular zone, enter the zone number
followed by the COMMAND key when the keypad is displaying the
Status List.
Armed Status
With Armed Status, the keypad displays the current armed
condition of areas within your security system.
The keypad displays
When
HOME MODE ON
The perimeter area is on in a Home/
Away system
PERIMETER ON
The perimeter is armed in an All/
Perimeter system
ALL SYSTEM ON
All areas are on
SLEEP MODE ON
The perimeter and interior areas are
on but the bedroom area is off
Also, for keypads that include an Armed LED, the Armed LED is ON
steady anytime a burglary protection area is armed and OFF when
ALL areas are disarmed.
Exit Error
An automatic function of the panel that prevents an alarm from
occurring if an exit door does not close all the way after the
system has been armed. For example, if the front door is left
ajar upon exit and the exit delay time has expired, the system
attempts to arm the front door zone but recognizes the open
condition and, instead of sending an alarm report to the central
station, sends an Exit Error report and force arms the door. (If
the door closes at a later time it will be included back into the
system.) The system sounds the alarm sirens for 15 seconds to
alert you of the condition and provide an opportunity for you to
close the door.
The Exit Error feature allows the central station to acknowledge
the arming error without dispatching the police on a false alarm.
Technical Manuals Online! - http://www.tech-man.com
Содержание XRSuper6
Страница 1: ...User s Guide r6 Technical Manuals Online http www tech man com ...
Страница 4: ...This page intentionally left blank Technical Manuals Online http www tech man com ...
Страница 38: ...This page has been intentionally left blank Technical Manuals Online http www tech man com ...
Страница 39: ...LT 0622 10 02 Technical Manuals Online http www tech man com ...