37
Description :
Part No.:
Complete double ducting system including
: 2 elbows 90º, 2 telescopic
lengths, 2 grill supports and 2 black grills
7B30ZK-1
Complete
single
ducting
system including :2 x 6" lengths, 1 decorative black
frame and 1 black louver
7B26ZKS-1
Complete
single
ducting
system including :2 x 6" lengths, 1 decorative brass
frame and 1 brass louver
7B26ZKSB-1
Black grill with support
7B30ZO
Brass grill for 7B30ZK
7B30ZGB
1 brass louver & 1 decorative brass frame
7B26ZKSLB
Elbow 90º, 8" dia.
7B26ZE90
Elbow 45º, 8" dia.
7B26ZE45
Telescopic length, 8" dia.
7B26ZLA
Adjustable length, 8" dia. (2" - 5")
7B26ZL2A
Radiation shield
7B26ZR
Central forced air kit including
: adaptor and 2 clamps (BISAF), Blower
(BISZY), Blower variable speed control (VRUW), Thermo-disk (VTU)
and fan to flex adaptor (BISAVF).
BISFWK-1
Flex adaptor and 2 clamps
BISAF
Flexible pipe 5" D.I. x 15 ft. Long
5FLEX15
Flexible pipe 5" D.I. x 30 ft. Long
5FLEX25
Blower (250CFM)for central forced air kit
BISZY
Blower variable speed control with decorative wall plate for (BISZY)
VRUW
Thermo-disk, on/off blower control for (BISZY)
VTU
Thermostat 24V kit (heating and cooling)
HCTW
Back draft damper
BISBD
Adaptor for fan to flexible pipe
BISAVF
Other Options:
Panel for clean face option
BISCF
Rigid fire screen
BISZN-1
Heat activated on/off pre-wired fan kit
UZY3
Masonry chimney adaptor
BISUMA
7.
APPENDIX
SPECIFICATIONS
Weight
412 lbs.
Height
40 1/2"
Width
38"
Depth
24 1/2"
Chimney weight ASHT+ (7" dia.):
6.25 lbs./ft.
Chimney weight S2100+ (7" dia.):
10.8 lbs./ft.
CLEARANCE TO COMBUSTIBLES
The following clearances meet the minimum requirements for a safe installation
Side wall:
24" (457 mm) measured from the doors edge
Ceiling:
6’ 8" (2032 mm) measured from the base of the fireplace
Fireplace enclosure:
Bottom: 0"
Side: 0"
Back: 0"
Top: Do not fill the space above the fireplace with any material
Chimney:
2" (50 mm)
Mantel:
48" (1219 mm) measured from the base of the fireplace.
REPLACEMENT PARTS
Rear baffle refractory
PR-SR1965
Front baffle refractory
PR-SR1968
Содержание EPA BIS ULTRA
Страница 2: ...Printed in Canada Rev 9 April 2007 PIBISULTRAEPA ...
Страница 7: ...2 2 CERTIFICATION LABEL ...
Страница 10: ...5 ...
Страница 20: ...15 Figure 7 Figure 9 Figure 8 Figure 10 ...
Страница 30: ...25 Figure 28 NOTE THE OUTSIDE AIR KIT IS MANDATORY FOR BOTH FIREPLACE AND CHIMNEY ...
Страница 35: ...30 Figure 31 Figure 32 ...
Страница 37: ...32 ...