The doors must be installed only
when the installation of the BIS
ULTRA is completed. All you have
to do is fit the male part of the hinge,
already fixed on the doors, in the
female part, which is already fixed
on the fireplace.
To remove the doors, simply pull
the doors up from the hinges.
The adjustment of the doors has
been set at the factory. If the fit is
still not perfect, you can adjust the
doors using the hinge screws (see
fig.4).
Figure 3
3.3.8 Door Adjustment
The doors may need to be adjusted
to be completely airtight. For a door
to be considered air tight, a piece of
paper cannot be inserted in between
the façade of the fireplace and the
door gasket. The gasket air
tightness can be adjusted using the
adjustment screw located on the
fireplace façade at the bottom of the
fireplace opening. (An Allen key #
1/8
will
be
necessary
for
adjustment).
Figure 4
3.3.9 Glass Care - Replacement
The glass used for the BIS ULTRA is a high temperature ceramic glass. If the glass
breaks, it must be replaced with a ceramic glass. Tempered glass or ordinary glass will not
withstand the high temperatures of the BIS ULTRA. Replacement glass should be
purchased from a Security Chimneys International dealer. Do not operate the unit with
cracked or broken glass.
3.3.10 Glass Care - Cleaning
The BIS ULTRA is designed to keep the glass clean under normal operating conditions. If
the BIS ULTRA is operated continuously with the combustion air damper closed, the
glass will tend to get dirty unless the fuel, firebox and glass are maintained at hot
temperatures (see "Refuelling For Best Performance”). To clean the glass, there are a
number of specially designed cleaners. Your authorised Security Chimneys International
dealer can recommend a suitable cleaner which is available in your area. Regular
Содержание EPA BIS ULTRA
Страница 2: ...Printed in Canada Rev 9 April 2007 PIBISULTRAEPA ...
Страница 7: ...2 2 CERTIFICATION LABEL ...
Страница 10: ...5 ...
Страница 20: ...15 Figure 7 Figure 9 Figure 8 Figure 10 ...
Страница 30: ...25 Figure 28 NOTE THE OUTSIDE AIR KIT IS MANDATORY FOR BOTH FIREPLACE AND CHIMNEY ...
Страница 35: ...30 Figure 31 Figure 32 ...
Страница 37: ...32 ...