background image

ProLogic B22 

Operation Instructions 

 

24 

 

(1) Lock Body 
(2) Shoulder bolt for Entrypad  
(3) Mounting Screw for Lock  
(1) Operation Manual 
*Battery NOT included 
*Smartphone NOT included 
 
16.0 FCC Warning 
 
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 
(1) This device may not cause harmful interference, and (2) this device must accept any interference 
received, including interference that may cause undesired operation. 

Any changes or modifications not expressly approved by the party responsible for compliance could void 
the user's authority to operate the equipment. 

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 
harmful interference in a residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 
interference to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

-- Reorient or relocate the receiving antenna. 

-- Increase the separation between the equipment and receiver. 

-- Connect the equipment into an outlet on a circuit different from that to which the receiver is 
connected. 

-- Consult the dealer or an experienced radio/TV technician for help. 

To maintain compliance with FCC’s RF Exposure guidelines, this equipment should be installed and 
operated with minimum distance between 20cm the radiator your body: Use only the supplied antenna. 

Specific Absorption Rate (SAR) information: 

This Mobile Phone meets the government's requirements for exposure to radio waves. The guidelines 
are based on standards that were developed by independent scientific organizations through periodic 
and thorough evaluation of scientific studies. The standards include a substantial safety margin designed 
to assure the safety of all persons regardless of age or health. 

Содержание EC-1701A-B22-II

Страница 1: ...4 4 Delete One User 4 5 Delete All Users 4 6 Delete Phone 5 0 Smartphone Management 5 1 Pair Phone 5 2 Delete Phone 6 0 System Identification 6 1 System Info 7 0 Lock Settings 7 1 Factory Reset Firmw...

Страница 2: ...is connected to the Entry Pad Step 2 Ensure the lock cable is disconnected from the lock body Step 3 Locate the Reset Hole on the back of the lock under the QC sticker Step 4 Using a paper clip depre...

Страница 3: ...itioned so that it lies in the channel on the back of the lock This channel is provided to protect the lock cable from damage or crimping during installation Using the provided lock bolts secure the l...

Страница 4: ...Programmed Lock Status After this initial power up it will check to ensure that the system is communicating correctly The display will read Link with Lock OK If the Display reads Fail to Link with Loc...

Страница 5: ...end the code to the lock Note the additional 3 masking digits can be added before and or after your code 3 0 Set Date and Time 3 1 Set Clock Time Step1 Press the Menu OK button Step 2 At My Menu press...

Страница 6: ...OK button Step 2 At My Menu press the Menu OK button Step 3 The display will prompt you to enter a code enter a valid Super or Manager Code and press Menu OK Step 4 Scroll to the menu selection Chang...

Страница 7: ...ill prompt you to enter a code enter a valid Super or Manager Code and press Menu OK Step 4 After logging in the screen will show Users Press Menu OK Step 5 Next the screen will show Enroll Manager2 P...

Страница 8: ...r Manager Code and press Menu OK Step 4 After logging in the screen will show Users Press Menu OK Step 5 Next the screen will show Enroll New User Press Menu OK Step 6 Now enter a 6 digit code Step 7...

Страница 9: ...t then select the user to be deleted through the or button and finally press the Menu OK button to prompt the screen Step 7 Press Menu OK This User Code is now deleted from the system 4 5 Delete All U...

Страница 10: ...l users are deleted 5 0 Smartphone Management The ProLogic B22 uses a smartphone to allow for remote management and control Download the SECURAM app on the App Store for iPhones or on the Google Play...

Страница 11: ...Phone This feature is used to remove any mobile device connected to the system Step1 Press the Menu OK button Step 2 At My Menu press the Menu OK button Step 3 The display will prompt you to enter a c...

Страница 12: ...Press the Menu OK button Step 2 Press the button to the menu selection System Info Step 3 Press Menu OK and the screen will display information about the system This menu selection can be accessed wi...

Страница 13: ...screen will now show Factory Reset press Menu OK Step 6 Press Menu OK to confirm Step 7 The screen will prompt the following and complete the factory reset 7 2 Show Audit Trail Step1 Press the Menu OK...

Страница 14: ...ogic B22 has a built in vibration sensor The vibration sensor will send a notification to the app in the event that the safe is being attacked By default the Vibration sensor is enabled Step1 Press th...

Страница 15: ...APP 7 4 Set Vibration Sensitivity This menu will appear only if Vibration Alert is enabled Please refer to 7 3 to enable Vibration Sensor There are five levels of vibration sensitivity with Level 1 re...

Страница 16: ...he app you may want to either move the Smart Hub closer to the safe lock or set the Battery Efficiency to LOW power consumption will increase but the communication will be more stable To set the Batte...

Страница 17: ...hanged from the default setting this value must be maintained as it is a vital element to communicate with the lock inside the safe Step1 Press the Menu OK button Step 2 Press the button to the menu s...

Страница 18: ...provement over other commonly used reset functions as it offers a very secure recovery method 9 1 Recovery Code Set The default Recovery Code for the ProLogic Series is 999999 It is not necessary to c...

Страница 19: ...onsive to commands and may need to be reset Step1 Press the Menu OK button Step 2 Press the button to the menu selection Recover System and press Menu OK Step 3 To confirm the action press Menu OK The...

Страница 20: ...g mode the following Mechanical Reset procedure must be followed Step 1 Ensure that the EntryPad is not connected to the lock and that the battery is connected to the EntryPad Step 2 Find the reset ho...

Страница 21: ...er or Manager Code and press Menu OK Step 4 The display will prompt you to enter the new code for the user Step 5 Repeat the user code Code has been successfully enrolled 10 2 Delete User Menu OK 2 St...

Страница 22: ...et Recover System Sub Menu Super Manager Codes Users Pair Phone Change My Code My Finger Lock Settings Set Time Set Cancel Time Delay 2nd Level Sub Menu Users Enroll New User Delete One User Delete Al...

Страница 23: ...use this product within the temperature range of 0 C 49 C This device is to be used indoors only Child Safety This device and its accessories may contain small parts Keep the device and its accessorie...

Страница 24: ...radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception whic...

Страница 25: ...e user s body and the handset including the antenna Third party belt clips holsters and similar accessories used by this device should not contain any metallic components Body worn accessories that do...

Страница 26: ...their product for this 12 month Consumer Purchase Warranty upon installation or receipt of their safe lock The Consumer Purchase Warranty Registration form is packaged with each product 18 0 Contact...

Отзывы: