background image

Confidant RFID 

Complete Lock with ASM Mortise / 

Tubular Latch

Installation instructions

PK3621-T - 2019 - 02

EN

Содержание 4652A-CRFID

Страница 1: ...Confidant RFID Complete Lock with ASM Mortise Tubular Latch Installation instructions PK3621 T 2019 02 EN ...

Страница 2: ...enter of the Installation Guide Model Confidant RFID IC 4652A CRFID FCCID Q8SCONFIDANT RFID Regulatory Compliance This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Any changes or modi...

Страница 3: ...RTANT Please read and follow all directions carefully Wear safety glasses when making the holes CAUTION WARNING IMPORTANT Carefully inspect windows doorframe door etc to ensure that the recommended procedures will not cause damage Kaba Lodging Systems standard warranty does not cover damages caused by installation Respect applicable building codes regarding handle height Note that the centerline o...

Страница 4: ...4 Confidant RFID ASM Mortise Tubular Latch PK3621_T 02 19 Inside Trim with Thumbturn Inside Trim without Thumbturn 2 Inventory American Steel Mortise ASM Hardware Bag ASM Mortise ...

Страница 5: ...Confidant RFID ASM Mortise Tubular Latch PK3692_T 02 19 5 2 Inventory Tubular latch Hardware Bag Tubular Latch Inside Trim with Thumbturn Inside Trim without Thumbturn ...

Страница 6: ... Tubular Latch PK3621_T 02 19 3 Install Spindle 1 Check Handing Adjust for Right Hand RH or Left Hand LH 2 Insert Spindle 3 Attach and Clamp Spindle Clip to Spindle as shown RH LH Ensure legs are firmly clamped against the spindle ...

Страница 7: ...fidant RFID ASM Mortise Tubular Latch PK3692_T 02 19 7 4 Install Outside Lever Left Hand 1 1 2 2 Right Hand Note Hold down the outside lever against the outside housing while tightening the lever set screw ...

Страница 8: ...K3621_T 02 19 Handing RH to LH 5B Prepare Inside Housing 5A Adjust Handing Tubular Latch lock with Privacy Only Inside Right Hand Housing Handing LH to RH Inside Left Hand Housing 1 Remove 1 Remove 2 Rotate 180 2 Rotate 180 3 Assemble 3 Assemble ...

Страница 9: ...able only for multihousing locks or locks with automatic dead bolt LH ASM ASM RH Automatic Dead Bolt Version American Steel Mortise Version Back Plate Rear Back Plate Front To change the turn knob stopper from LH to RH push stopper from FRONT See 1 Assemble it in the REAR Follow the arrows as shown Spring NOT required for Automatic Dead Bolt ADB versions RH RHR LH LHR ...

Страница 10: ... PK3621_T 02 19 6 Install Lock on Door ASM Tubular Latch Assemble spacers on screws See Annex B for exterior applications CAUTION WARNING IMPORTANT After connecting all cables make sure all excess cables are pushed inside the hole s in the door ...

Страница 11: ...om Door is Open A Present Test Keycard B Check Green Red Lights Flash C Rotate Outside Lever to Check Bolt Retraction D Release Outside Lever Should Move Freely E Rotate Inside Lever to Check Bolt Retraction F Check Bolt Projection from Thumbturn 7 Install Inside Trim Cover Thumbturn must be vertical if applicable 1 2 3 ...

Страница 12: ...ock With Jack Cable CAUTION WARNING IMPORTANT For security reasons lock must be programmed BEFORE installing the battery door Every time the bat tery door is removed pass an emergency card or connect lock to FDU M Unit to reset the tamper alarm Audit information is not affected CAUTION WARNING IMPORTANT ...

Страница 13: ... screws of efficient lenght to engage the structural stud behind the frame Use only the strike and dust box supplied Use of non approved parts may void the warranty CAUTION WARNING IMPORTANT For Auto Deadbolt models the gap between the mortise front plate and the strike must not exceed 1 4 Annex A Installation of Standard ASM Mortise Door Door Frame Mortise Max 1 4 For LH left hand and RHR right h...

Страница 14: ...b H using a screwdriver until the deadbolt D extends approximately 1 4 D 1 4 H Proceed to step 3 For Autodeadbolt ASM rotate hub H until the deadbolt D is fully retracted The deadbolt will extend approx 1 16 from the mortise case D 1 16 H Hold deadbolt D gently Press and release the auxiliary latch X You should feel the deadbolt trigger and begin to extend under the force of the spring D hold gent...

Страница 15: ...ing a small screwdriver L T S part 027 510382 Continue to hold tool S Release the latch bolt L and keep the anti friction latch F toward the flat side of the latch bolt so that the bolt extends fully L F S 4 Pull out the latch bolt L until it just clears the front plate Note If you remove the bolt completely you must turn it 90 to re insert it L 180 Rotate the latch bolt L 180 Re insert it to the ...

Страница 16: ...atch X is a crescent shape remove it turn it 180 and replace it The auxiliary latch slides easily in and out of the mortise X crescent must be reversed 180 re insert 7 Assemble back screw V and lock washer W if appli cable The screw V must be tightened CAUTION WARNING IMPORTANT Screw V must not touch the back wall of mortise cut out on the door 8 The mortise should look like the diagram below Chec...

Страница 17: ... Mortise Tubular Latch PK3692_T 02 19 17 Annex B Install Outside Housing with Gasket Exterior and Ocean Front Versions Annex C Remove Battery Holder A C B D Unscrew Unclip Battery Holder Remove Door Remove Battery Holder ...

Страница 18: ...ular Latch PK3621_T 02 19 1 3 A 3 B 2 5 4 Annex D Install Bluetooth and Messenger module Battery must be disconnected before adding Bluetooth and Messenger module See Annex E for instructions of how to remove the cover from the module ...

Страница 19: ...le MESSENGER A MESSENGER B 1 2 3 4 5 6 How to change orientation of Messenger antenna board The lock is provided with orien tation of board for Messenger hub outside the room Orientation when Messenger hub outside the room Orientation when Messenger hub inside the room Position of Bluetooth antenna board ...

Страница 20: ...20 Confidant RFID ASM Mortise Tubular Latch PK3621_T 02 19 SEE DETAIL X DETAILX SCALE 1 1 Annex E Remove cover of Bluetooth and Messenger module ...

Страница 21: ...Confidant RFID ASM Mortise Tubular Latch PK3692_T 02 19 21 ...

Страница 22: ...r Services Support Ilco 1 877 468 3555 1 514 340 9025 Saflok 1 800 999 6213 1 248 837 3700 General Information www kabalodging com Online Consumable Orders www ilcostore com www saflokstore com To access all of our easy steps please visit our Support Website www kabalodgingsupport com ...

Отзывы: