![Securakey Radio Key RKDT-SA-M Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/securakey/radio-key-rkdt-sa-m/radio-key-rkdt-sa-m_operating-manual_1231642025.webp)
Selections are:
6.
Normally Open (Factory default)
7.
Normally Closed
8.
SecuRelay™ Option.
For example, to configure the relay normally closed, the
following sequence would be used:
(ENTER)
(THRU)
(THRU)
+ + 7 +
Using the RKDT-SA-M/SA-S as a Wiegand Output Reader
The RKDT-SA-M/SA-S can be connected to a multidoor access
control system (such as the Secura Key SK-ACP) using the
Wiegand output. When any Radio Key
®
or HID
®
Proximity
card or tag is presented to the unit, whether or not it has been
programmed into the unit, the appropriate facility code and card ID
and parity bits will be sent out via the white and green wires.
When outputting Wiegand formatted data from HID
®
cards, the
bits are transmitted exactly as they are encoded on the card.
The reader does not perform any internal processing, such
as adding additional bits, calculating checksums, offsets, or
decrypting any data.
Radio Key
®
RKDT-SA-M/SA-S Operating Guide
Secura Key
21