Lost or forgotten Password
If the password is lost or forgotten, it can be restored to the factory
default (12345). Remove the Radio Key
®
RKDT-SA-M/SA-S
unit from the wall and disconnect power. With the Data 1 line
(white wire) temporarily connected to the Remote open line
(brown wire), restore power. The factory default (12345) is
now in effect. The LED will flash alternately Red and Green.
While this is occurring, set the Facility Code or Codes in the
reader (see below). Remove power and reconnect the unit for
operation, restore power and remount the unit. This procedure
will NOT delete any cards or tags from reader’s memory.
Restore All Default Settings
To reset all Factory Defaults and clear the reader memory of
all cards, put the unit in Program Mode, then press the “THRU”
key two times, press “9” two times, then press ENTER.
Setting Facility Code(s)
Before any cards are added to the RKDT-SA-M/SA-S you must
set the Facility Code or Codes. When a new reader is first
powered up the LED should be flashing alternately Red and
Green. This indicates that the unit is in the “Learn Facility Code”
mode. You can also place a reader in this mode by entering
Radio Key
®
RKDT-SA-M/SA-S Operating Guide
Secura Key
10