T5 Delay
Enabled / Disabled
When Enabled, T5 is delayed by 20ms ± 50%
P/N Pairs Swapping
Enabled / Disabled
Enable or disable LVDS Differential pairs swapping (Positive
Negative)
Pairs Order Swapping
Enabled / Disabled
Enable or disable channel differential pairs order swapping (A
D, B
CLK, C
C)
Bus Swapping
Enabled / Disabled
Enable or disable Bus swapping (Odd
Even)
Firmware PLL
0: +/- 1.56%
1: +/- 3.12%
2: +/- 6.25%
3: +/- 12.5%
4: +/- 25%
5: +/- 50%
6: +/- 100%
Set Firmware PLL range
4.3.16
SMBIOS Information
Display only screen, shows information about the module and the Carrier board.
4.3.17
Embedded Controller submenu
Menu Item
Options
Description
Power Fail Resume Type
Always ON
Always Off
Last State
Specifies what must happen when power is re-applied after a power failure (G3 state).
Always ON: the System will boot directly as soon as the power is applied.
Always OFF: the system remains in power off State until power button is pressed
No C-MOS battery handling
Disabled / Enabled
This option is enabled when
“
Power Fail resume Type
”
is set to Always OFF or Last State.
In system with no C-MOS battery, the chipset always powers on after a power failure: Always OFF
Resume Type or Last State when Last State was OFF will therefore require an immediate shutdown
OUT 80 serial redirection port
None
1
2
1+2
Selects which Embedded Controller
’
s UART(s) will receive OUT 80 (Post Codes)
Hardware Monitor
By selecting this item, an information screen with System parameters will appear
Reset Causes Handling
By selecting this item, an information screen with the handling of latest resets causes will appear
Super IO Configuration
See Submenu
Sets the parameters for Serial Ports
Internal FAN Settings
See Submenu
Sets the parameters for internal (i.e. on module) FAN