4.3.12
Platform Trust technology submenu
4.3.13
Main Thermal Configuration submenu
4.3.14
HSUART Transceiver Configuration submenu
Menu Item
Options
Description
fTPM
Enabled / Disabled
Enable/Disable fTPM
Menu Item
Options
Description
Critical Temperature (°C)
Settable Threshold (°C)
[80 .. 110]
Above this threshold, an ACPI aware OS performs a critical shut down. Allowed range is from 80 to 110 included,
where 110 means disabled.
Passive Cooling
Temperature (°C)
Settable Threshold (°C)
[60 .. 105]
Above this threshold, an ACPI aware OS begins to lower the CPU speed. Allowed range is from 60 to 105 included,
where values not below Critical Temperature mean disabled.
TC1
[0...16]
Thermal Constant 1: part of the ACPI Passive Cooling Formula
TC2
[0..16]
Thermal Constant 2: part of the ACPI Passive Cooling Formula
TSP (seconds)
[2..32]
Period of temperature sampling when Passive Cooling
Menu Item
Options
Description
HSUART #0 Interface
RS-232
RS-422
RS-485
Select among RS232 (default), RS-422 or RS-485 interface. When selecting RS-422 or RS-485, the following menu
item will appear
HSUART #0 RX termination
Disabled / Enabled
RX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm RX Termination.
HSUART #0 TX termination
Disabled / Enabled
TX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm TX Termination.
HSUART #2 Interface
RS-232
RS-422
RS-485
Select among RS232 (default), RS-422 or RS-485 interface. When selecting RS-422 or RS-485, the following menu
item will appear
HSUART #2 RX termination
Disabled / Enabled
RX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm RX Termination.
HSUART #2 TX termination
Disabled / Enabled
TX termination can be enabled when RS-422 or RS-485 is selected.
Disable (default) or enable 120 Ohm TX Termination.