background image

 

 

 

 

 

 

 

Secabo GmbH   Hochstatt 6-8   85283 Wolnzach   Germany   [email protected]   www.secabo.com 

 

17 

 

Содержание TCC SMART

Страница 1: ...mooth production launch with your new device Any type of reproduction of this operating manual requires the written permission of Secabo GmbH Modifications to and errors in the technical data and or p...

Страница 2: ...wool should only be done inside a closed bag Ensure that neither liquids nor metal objects reach the inside of the heat press Make sure you use a grounded wall socket Keep in mind that a heat press m...

Страница 3: ...ms included Mechanical base of the heat press with heating element and base element Controller box C13 Cold device cable Secabo GmbH Hochstatt 6 8 85283 Wolnzach Germany mail secabo com www secabo com...

Страница 4: ...ary pushbutton d Power socket and ground connection Controller not shown internal connections e Clamping lever for transfer objects f Exchangeable base element g Heating element and heating element co...

Страница 5: ...box slide into the slots at the base frame Securely tighten the hand nuts Attach the small 6 pin plug from the rear side of the base frame to the appropriate socket on the outer right side of the cont...

Страница 6: ...plied C13 cold device cable into the back of the controller box and connect it to a safety socket which must be equipped with a grounded connection protection via fuse and ground fault circuit interru...

Страница 7: ...ller components and operation Display components and their meaning Area for time setting and countdown when press is closed Secabo GmbH Hochstatt 6 8 85283 Wolnzach Germany mail secabo com www secabo...

Страница 8: ...ating up or cooling down Below the set temperature the arrow is flashing upwards Indicator for management of memory slots Counter for counting the performed press operations How to use the controller...

Страница 9: ...the set value If no input occurs for 5 seconds input mode ends automatically Pressing exits input mode the set value is not applied and the display returns to the current ACTUAL value Temperature rel...

Страница 10: ...the preset time and is deactivated again upon completing the press operation When activated the Time Pre symbols will light up in the lower part of the display with the corresponding time indicator Th...

Страница 11: ...lues to blank or currently used memory slots first push and hold the rotary knob flashes then select the desired memory slot then hold the knob until the values and symbols flash briefly The values ar...

Страница 12: ...et the time value to 0 The active Sleep Mode can be exited at any time by pressing any button or by actuating the press lever The press will then restore the previously set parameters 6 Auto Off Setti...

Страница 13: ...activated on your smartphone Simply select the respective heat press from the list to connect to it If you have changed the Bluetooth PIN on the heat press the app will prompt you to enter it in the...

Страница 14: ...sing the key You can adjust the contact pressure by turning the small hand screw at the bottom of the press to increase or decrease the distance the lever travels Turning the knob clockwise increases...

Страница 15: ...the wall socket Only perform maintenance work after consultation with our technical support team The press should be cleaned regularly using a soft cloth and a mild household cleaner to remove adhesi...

Страница 16: ...of the material Important note You should perform your own tests with the respective transfer materials and carrier media prior to each production The aforementioned values as well as any manufacture...

Страница 17: ...Secabo GmbH Hochstatt 6 8 85283 Wolnzach Germany mail secabo com www secabo com 17...

Страница 18: ...i Pressure setting Height adjustment of the base element via handwheel Power supply 230V 50Hz 60Hz 1 0kW Environment 5 C 35 C 30 70 relative humidity 41 F 95 F 70 relative humidity Weight without pack...

Страница 19: ...of the following EC Directives and Harmonized Standards EG Richtlinien EC directives 2014 35 EG Niederspannungsrichtlinie 2014 35 EC Low Voltage Directive 98 37 EG Maschinenrichtlinie 2006 42 EG vom...

Отзывы: