3.11 Change user’s password
3.11.1 Change password by card
* Swipe user card (Old user password) # (New password ) # (New password) #
Example, Change user password by card:*,Swipe user card 1234#123456#123456#
Note: A initial password 1234 will be generated when adding a new card user. The initial password
can’t open the door, Just can be used to change the card user’s password. The new password
should be in 6 digits.
3.11.2 Change password by ID number
* (ID number) # (old password) # (new password) # (new password) #
Example Change user’s password by ID, *1#123456#111111#111111#
Note: when changing password by ID number, the old user password can not be initial password
1234
3.12 User to open the door
Read the card, or enter 6 digits user’s passwords, or press the Exit button
Note: No pressing # key after entering the password reduces frequency of using # key and greatly
improves the service life of # key. When opening the door, there will be a long sound of "beep"
and the indicator light will turn green during unlock. when the opening mode is card and
password, the interval between reading card and enter the password cannot exceed more than 5
seconds.
3.13 Resetting To Factory Default Setting
When administrator password is out of mind, or after user randomly adjust various parameters,
you can return to the normal situation by resetting to factory default setting. As following:
power off, press *and hold it, then power on, release it until hear two beeps, and master password
will revert to 888888,
And the keypad parameters are reset to factory default setting, detail is in the “administrator
mode operation summary table”, the user’s card and password won’t be deleted.
4. Administrator mode operation summary table