1.3 Functional component

1.4 Technical parameters

> Working voltage: DC12±2V
> Static current: ≤20mA
> Operating current: ≤100mA
> Drive electric lock current: ≤3A
> Working environment temperature: -20~50°C
> Working environment humidity: 0~95% (no condensation)
> Maximum card reading distance:5cm

2  Installation, wiring and Debugging

2.1 Installation

Unscrew the anti-tamper screw on the bottom of the product with the special anti-tamper 
screwdriver, remove the back case of the product, then according to the opening position of the 
back case, use the impact drill to open the corresponding holes on the wall, make a hole with 
diameter larger than 8mm, and four holes with diameter of 6mm, then insert four matching plastic 
expansion screws, and fix the back case to the wall with four matching self-tapping screws.
As shown below:

Button

 

frame

 

indicator

LOGO

 

Indicator light

Metal Key

Card reader antenna

Metal body

Содержание BC2019

Страница 1: ...and the user can modify password by himself Opening door modes card card password card or password password Opening time 50mS 1 98 seconds for normal mode 99 seconds for switch mode It can connect wi...

Страница 2: ...tamper screw on the bottom of the product with the special anti tamper screwdriver remove the back case of the product then according to the opening position of the back case use the impact drill to o...

Страница 3: ...screws and fix them As shown below The correspondence between the color of wire and their function Door Strike Relay NC Door Strike Relay NO Door Strike Relay Com Alarm Switched negative when active T...

Страница 4: ...orange Under administrator mode it will automatically exit to standby state if there is no operation within 30 seconds Under non administrator mode it will automatically exit to standby state if there...

Страница 5: ...rd For example consecutively set 3 passwords with ID numbers 4 5 and 6 14 444444 5 555555 6 666666 3 4 Deleting users There are three ways to delete a user where the ID number ranges from 0 to 999 eve...

Страница 6: ...in buzzer will ring Close the door swipe the valid card or input correct user PIN Code wait for more than 1 minutes will release alarm 2 If the door was opened by force or open the door after 120 sec...

Страница 7: ...button Note No pressing key after entering the password reduces frequency of using key and greatly improves the service life of key When opening the door there will be a long sound of beep and the ind...

Страница 8: ...Solution Unusual Indicator light Power voltage too low or too much interference Change to qualified power supply cable or restoring power No response Continuously swipe in lock mode or input the pin...

Отзывы: