2.3 Debug

Turn on the power supply and test according to the instructions. The debugging will be completed 
until the lock can be opened correctly by reading card, password and exit button.

3 Basic functions

Operating conventions:
> A long sound"Di-"indicates correct operation. Three short sounds"Di Di Di"indicate wrong 
   operation . The indicator light flash in green means operate correctly.
> "#"indicate confirm completed, normally used behind pass word, ID number, or parameter.
> "*"indicate cancel the current operation or return to the previous menu.
> The management menu is fixed to 1 digit from 0-6, cannot press key"#"after it. After entering 
    setting menu, the indicator light turns to orange.
> Under administrator mode, it will automatically exit to standby state if there is no operation 
    within 30 seconds. 
> Under non- administrator mode, it will automatically exit to standby state if there is no operation 
   within 5 seconds. 

Light and buzzer indication:

3.1 Enter into administrator mode

  *   6 digits administrator password   #
888888 is the default factory administrator code. It fixed to 6 digits.
For example, press *888888* to enter into administrator mode. 
Enter into the administrator mode first before start the below operations.

operation status

Light color

Buzzer

Standby

Red

PIN inputting

Red flash

Read the card in Card & PIN mode

Red flash

Enter into a

dministrator

mode

Red flash

Enter menu setting status

Orange

Successful operation

Green

A long sound

Unlock the lock

Green

Press numeric key

A short sound

Press *

A long sound

Failed operation

Three short sound

Содержание BC2019

Страница 1: ...and the user can modify password by himself Opening door modes card card password card or password password Opening time 50mS 1 98 seconds for normal mode 99 seconds for switch mode It can connect wi...

Страница 2: ...tamper screw on the bottom of the product with the special anti tamper screwdriver remove the back case of the product then according to the opening position of the back case use the impact drill to o...

Страница 3: ...screws and fix them As shown below The correspondence between the color of wire and their function Door Strike Relay NC Door Strike Relay NO Door Strike Relay Com Alarm Switched negative when active T...

Страница 4: ...orange Under administrator mode it will automatically exit to standby state if there is no operation within 30 seconds Under non administrator mode it will automatically exit to standby state if there...

Страница 5: ...rd For example consecutively set 3 passwords with ID numbers 4 5 and 6 14 444444 5 555555 6 666666 3 4 Deleting users There are three ways to delete a user where the ID number ranges from 0 to 999 eve...

Страница 6: ...in buzzer will ring Close the door swipe the valid card or input correct user PIN Code wait for more than 1 minutes will release alarm 2 If the door was opened by force or open the door after 120 sec...

Страница 7: ...button Note No pressing key after entering the password reduces frequency of using key and greatly improves the service life of key When opening the door there will be a long sound of beep and the ind...

Страница 8: ...Solution Unusual Indicator light Power voltage too low or too much interference Change to qualified power supply cable or restoring power No response Continuously swipe in lock mode or input the pin...