Sebury BC2019 Скачать руководство пользователя страница 1

Instruction ManualV1.0

1  Product overview

1.1 Product introduction

This product uses high-strength zinc alloy housing, Proximity card (EM card, also known as 
ID card) or password to open the door, built-in highly integrated micro-controller, simple 
circuit, safe and reliable, economical and durable, suitable for office, villa etc.

 

1.2  Product Features

> 1000 user cards bound with 1000 user passwords, and the user can modify password by himself
> Opening door modes: card, card + password, card or password, password.
> Opening time: 50mS, 1-98 seconds for normal mode, 99 seconds for switch mode;
> It can connect with the door magnetic detection for alarm or door closing prompts;
> Built-in high current MOS tube, can directly drive external alarm;
> Safe mode can be set: 10 times of invalid card or password will automatically lock the machine 
    for 10 minutes;
> Can  connect with an exit button, convenient to open the door from inside.
> Safety screw at the bottom to prevent malicious destroy. 

BC2019 Access control

Содержание BC2019

Страница 1: ...and the user can modify password by himself Opening door modes card card password card or password password Opening time 50mS 1 98 seconds for normal mode 99 seconds for switch mode It can connect wi...

Страница 2: ...tamper screw on the bottom of the product with the special anti tamper screwdriver remove the back case of the product then according to the opening position of the back case use the impact drill to o...

Страница 3: ...screws and fix them As shown below The correspondence between the color of wire and their function Door Strike Relay NC Door Strike Relay NO Door Strike Relay Com Alarm Switched negative when active T...

Страница 4: ...orange Under administrator mode it will automatically exit to standby state if there is no operation within 30 seconds Under non administrator mode it will automatically exit to standby state if there...

Страница 5: ...rd For example consecutively set 3 passwords with ID numbers 4 5 and 6 14 444444 5 555555 6 666666 3 4 Deleting users There are three ways to delete a user where the ID number ranges from 0 to 999 eve...

Страница 6: ...in buzzer will ring Close the door swipe the valid card or input correct user PIN Code wait for more than 1 minutes will release alarm 2 If the door was opened by force or open the door after 120 sec...

Страница 7: ...button Note No pressing key after entering the password reduces frequency of using key and greatly improves the service life of key When opening the door there will be a long sound of beep and the ind...

Страница 8: ...Solution Unusual Indicator light Power voltage too low or too much interference Change to qualified power supply cable or restoring power No response Continuously swipe in lock mode or input the pin...