9.
Clear blocked bore of injector with cleaning needle.
10. Check and clean outlet of F-connector in particular and injector plate holder in
general.
11.
Perform a complete descaling resp. rinsing cycle without mounted injector plate.
The cleaning needle
is also part of the
descaling kit.
Alternatively use a
pin or needle with
dia. 0.6 mm max. to clear
the injector bore. A piece
of polyamid fishing line
or nylon monofilament
with suitable diameter
can be used also.
It is important to flush the machine thoroughly prior to the assembly of
the injector plate. Otherwise remaining impurities can block the injector
again.