F U N C T I O N T E S T S
Heating up time
Test is passed if power button is turning green
- from 25 sec to 40 sec at 230 V mains voltage
- or within 60 sec at 100 V / 120 V mains voltage and 50 / 60 Hz mains
frequency.
1.
Plug into mains and press power
button.
2.
Measure the heating up time with a
stop watch (time until power button
stops blinking).
ON
OFF
46