Service manual
R E P A I R
4.
Apply a sufficient amount of standard heat conducting paste into socket (a) of ther-
moblock (pos. 15).
5.
Attach a new clamp spring (b, part of pos. 5) on the new NTC temperature sensor
(pos. 5).
6.
Tilt clamp spring on sensor body.
7.
Insert NTC temperature sensor in socket (a) partly so that both spring ends are in
the socket already.
8.
Place a piercer (or the blade of a screwdriver) on opposite clamp shoulder.
9.
Drive clamp spring down the socket with light blows of a hammer.
Assembly tip
•
Check that the new NTC temperature sensor is pressed down at the bottom of the
socket.
15
b
a
5
Use a pair of pliers to
fix the spring.
33