background image

GENERAL INFORMATION

NOTICE:

Model Number of your pump is located on the

pump shell. Record this number and keep in a safe place for
future reference in the event service is needed. 

The most important things you should know about your well
are: (1) its total depth; (2) depth to water; (3) draw down
water level. 

1. The well 

total depth

is the distance from the ground

level to the well bottom. 

2.

Depth to water

is measured from the ground level to the

water level in the well when the pump is not running.

3.

Draw down water level

is the distance from ground

level to the water level while water is being pumped. In
most wells, the water level drops when water is being
pumped. 

Usually you can obtain this information from your well
driller. Enter it in box at right. 

3

Record the following information at the
time of installation and retain it for future
reference: 

Pump Model No.

Control Center Model No.

Horsepower 

Volts 

Phase 

Hertz 

Full Load Amps 

Well Casing Diameter 

Well Depth 

Depth to Water 

Draw Down Water Level 

Table I - Pump Performance Chart (In Gallons Per Minute)

Residential Pumps with 1-1/4” Discharge

Discharge

Model

Pressure

Pumping Depth in Feet *

Number

H.P.

Voltage Stages

P.S.I.

20

40

60

80

100

125

150

175

200

250

300

350

400

390.285510

1/2

115

40

13.6

12.6

11.5

10.1

8.6

390.285520

1/2

230

6

40

13.6

12.6

11.5

10.1

8.6

390.284020

1/2

230

6

40

13.6

12.6

11.5

10.1

8.6

390.285530

3/4

230

8

40 

13.5

12.7

11.9

10.7

9.4

7.9

390.284030

3/4

230

8

40

13.5

12.7

11.9

10.7

9.4

7.9

390.284040

1

230

10

40

13.5

12.9

11.9

10.9

9.8

7.4

390.284050

1-1/2

230

14

40

13.5

12.9

11.7

10.4

8.9

7.1

High Capacity Pumps with 1-1/4” Discharge

Discharge

Model

Pressure

Pumping Depth in Feet *

Number

H.P.

Voltage Stages

P.S.I.

20

40

60

80

100

125

150

175

200

250

300

350

400

390.284060

1

230

7

40

26.4

24.7

22.7

20.7

18.4

390.284070

1-1/2

230

9

40

25.8

24.3

22.9

21.0

18.8

15.4

390.284080

2

230

12

40

26.4

25.1

23.7

22.2

20.8

17.2

390.284090

3

230

17

40

26.7

25.5

23.8

21.7

19.6

16.8

Pump

Control

Max

Fuse

AWG Cable Size

Model

Box

Load

Rating

No.

Type

No.

HP

Volts

Amps

(Amps)

12

10

8

390.285510

2-Wire

1/2

115

12.0

20

160

390.285520

2-Wire

1/2

230

6.0

15

650

1020

390.285530

2-Wire

3/4

230

8.4

15

480

760

390.284020

3-Wire

390.284120

1/2

230

6.0

15

650

1020

390.284030

3-Wire

390.284130

3/4

230

8.4

20

480

760

390.284040

3-Wire

390.284140

1

230

9.8

25

400

630

390.284060

3-Wire

390.284140

1

230

9.8

25

400

630

390.284050

3-Wire

390.284250

1-1/2

230

11.5

30

310

480

770

390.284070

3-Wire

390.284250

1-1/2

230

11.5

30

310

480

770

390.284080

3-Wire

390.284260

2

230

13.2

30

250

390

620

390.284090

3-Wire

390.284270

3

230

17.0

45

190

300

470

Max. Cable
Length in Feet –
Disconnect
switch to motor

}

}

Max. Cable
Length in Feet –
Disconnect
switch to motor

*Pumping depth in feet is the maximum distance to water from ground level. This maximum distance (drawdown water level) occurs while pump is operating. 

In most cases, when pump is not running, the water level will rise to a higher point in the well.

TABLE II - Fusing, Wiring and Cable Selection (Copper Conductors Only)

Содержание 390.284020

Страница 1: ...270 2 WIRE SUBMERSIBLE PUMP MODEL Nos 390 285510 390 285520 390 285530 CAUTION Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product Save This Manual For Future...

Страница 2: ...relief valve Stock No 27220 6 With a new well test well water for purity before using Consult your local Health Department for procedure Hazardous voltage Can shock burn cause death or start fires 7...

Страница 3: ...4 7 9 390 284030 3 4 230 8 40 13 5 12 7 11 9 10 7 9 4 7 9 390 284040 1 230 10 40 13 5 12 9 11 9 10 9 9 8 7 4 390 284050 1 1 2 230 14 40 13 5 12 9 11 7 10 4 8 9 7 1 High Capacity Pumps with 1 1 4 Disch...

Страница 4: ...pe Well Seal Purchase Locally Conduit or Sleeve Cable Splices Plastic Pipe Adapter Plastic Pipe Adapter Pump Check Valve Torque Arrester Purchase Locally Centering Guide 1178 0794 Plastic pipe adapter...

Страница 5: ...e Air and Standard The Air Volume Control AVC maintains the cushion of air in Standard Tanks No Air Volume Control is needed with a Captive Air Tank Air Volume Control A device mounted on a standard t...

Страница 6: ...oltage and frequency of the electrical power supply If in doubt check with your electric power company or a licensed electrician Check Fusing and Wiring Chart before connecting wires from pressure swi...

Страница 7: ...lder with a non acid soldering paste to solder the joint After splicing center the body of the insulator over the splice Slide the neoprene sleeves down into the recesses in the body as far as they wi...

Страница 8: ...e distance to the water level in the well are not known See page 4 The pump should not be set closer than 5 feet from the bottom of the well and should be submerged 15 to 20 feet below the draw down w...

Страница 9: ...in installation draw ings Figure 1 Page 4 Using teflon tape on all male threads Assemble this unit to the plastic pipe in same manner as outlined in Step 6 Assembly may slip through well seal Install...

Страница 10: ...om of the well 6 Develop the well See Well Development and Pump Test below 7 Refer to Typical Pump Installation Drawings for proper method of piping depending on the type of pres sure tank used Well d...

Страница 11: ...ve to restrict flow until discharge rate does not exceed well recovery rate possibly seriously damaging pump To prevent possibility of dangerous high pressure install a relief valve in discharge pipe...

Страница 12: ...color coding of drop cable Pressure switch fails A Voltage too low motor will run slowly A Have a competent electrician verify voltage at electrical disconnect box 2 wire or to shut off pump causing l...

Страница 13: ...4270 Description 1 U17 1172 U17 1173 U17 1174 U17 1174 U17 1174 U17 1175 Start Capacitor 2 U17 1184 U17 1185 U17 1186 Solid State Switch 3 U17 1201 U17 1201 U17 1201 Terminal Strip 4 U17 1190 U17 1191...

Страница 14: ...U36 197SS U36 197SS U36 197SS Nut 5 16 Hex 4 Required 3 U43 115SS U43 115SS U43 115SS U43 115SS U43 115SS U43 115SS Lockwasher 5 16 4 Required 4 P3 510P P3 510P P3 510P P3 511P P3 512P P3 513P Lead Co...

Страница 15: ...U43 115SS Lockwasher 5 16 4 Required 4 P3 517P P3 518P P3 519P P3 546SS Lead Cover 5 U30 840SS U30 840SS U30 840SS U30 840SS Screw 8 32x5 16 4 Required 6 U30 927SS U30 927SS U30 927SS U30 927SS Screw...

Страница 16: ...250 390 284130 390 284260 390 284140 390 284270 2 WIRE SUBMERSIBLE PUMP MODEL Nos 390 285510 390 285520 390 285530 The model number of your Submersible Pump will be found on a plate attached to the pu...

Отзывы: