FT430/440/450 INSTRUCTIONS

Seametrics • 253.872.0284 

Page 3 

seametrics.com

TABLE OF CONTENTS

GENERAL INFORMATION

The 

FT430/440/450

 flow computers are microcontroller-

based indicator/transmitters that interface with pulse 

output flow sensors to compute and display flow rate, flow 

total, and also generate output signals representing flow. 

The FT430 and FT450 have one scaled pulse output and 

one pulse pass through. The FT440 has two scaled pulse 

outputs. 
The FT450 is battery powered while the FT430 may be 

powered by an external DC power source or an optional 

internal AC power supply*. The FT440 is a “two-wire” or 

“loop powered” device, meaning that it is powered by the 

4-20 mA loop circuit itself. An optional internal AC power 

supply* is available for the FT440 with dual 24 and 12VDC 

outputs to power both the loop and sensors requiring 

more power than the loop can supply. 

Pulse and 4-20mA analog outputs can be used to signal 

external  devices,  e.g.  certain  metering  pumps  and  water 

treatment  controls.  Alternatively,  one  or  more  pulse 

outputs can be  configured as alarm outputs. These flow 

computers can be password protected to prevent resetting 

the total or changing configuration settings. 

The FT430/440/450 indicators are available in wall and 

meter mount configurations. The FT430 and FT440 models 

can also be panel mounted. 
Order the FT440 only if a 4-20mA output signal is a 

requirement and the FT450 if internal battery  power is 

needed. Otherwise the FT430 can be ordered.

*Internal power supply is available for the wall mount option only.

Features

Lower Housing

Setup Keys**

Electronics Module

Wall-Mount Brackets

Strain Relief Cable Gland

Display

**Includes password protection for tamper prevention when needed

Protective Cover (Optional)

Data Logger (Optional)

Sensus Smart Output (Optional)

Содержание FT430

Страница 1: ...PROUDLY MADE IN THE USA C e rtified Compa n y ISO ISO 9001 FT430 440 450 FT430 440 450 Rate Total Indicator Rate Total Indicator Instructions Instructions Optional Protective Cover Closed...

Страница 2: ...3 Wire Mechanical Meter Page 8 Connections for FT430 139 or FT440 139 115Vac Option Page 9 FT440 3 wire Mechanical Dual Scaled Pulse Output Page 9 FT440 EX Magmeter Page 10 FT440 139 EX Magmeter Page...

Страница 3: ...the loop and sensors requiring more power than the loop can supply Pulse and 4 20mA analog outputs can be used to signal external devices e g certain metering pumps and water treatment controls Alter...

Страница 4: ...Mega Liters Day Million Gallons Day Fluid Oz Second Minute Hour Day Barrels Second Minute Hour Day Total Units Gallon Gallon x 1000 Liters Mega Liter Cubic Meter Acre Feet Cubic Feet Cubic Feet x 100...

Страница 5: ...h or Low YES High or Low YES High or Low PULSE OUTPUT 2 SCALED FT430 FT440 Note 2 FT450 TYPE Not Available Current sinking Not Available MAX VOLTAGE 36 Vdc MAX CURRENT 100 mA MAX FREQUENCY 6 5 Hz PULS...

Страница 6: ...sing to the depression on the top of the flow sensor 5 Using an ordinary screwdriver inserted in one side of the slot see drawing tighten the screw as much as possible 6 Strip the wire ends make the c...

Страница 7: ...installed on the cord grip and must be snugly tightened on the cable or on a plug that would take the place of the cable Plugs with flanges are to be installed from the outside of the compression nut...

Страница 8: ...ER SENSOR ENGD _ _ S PULSE OUT 2 PULSE OUT 1 _ _ RED WHITE BLACK Micropower Flow Sensor FT450 Pulse Pass thru Pulse Responsive Metering Pump Current Sinking Polarity Sensitive Lithium C 3Vdc Replaceab...

Страница 9: ...40 139 115Vac Option POWER SENSOR ENGD _ _ S PULSE OUT 2 PULSE OUT 1 _ _ RED WHITE BLACK _ 9 30 Vdc Loop Power Supply Flow Sensor FT440 Electronic Metering Pumps _ S _ _ _ 4 20mA Device _ GROUND Conne...

Страница 10: ...orward Output Power M ax6m A 30Vdc 12 24Vdc _ _ White Green Red Black POWER SENSOR ENGD _ _ S PULSE OUT 2 PULSE OUT 1 _ _ FT440 GREEN WHITE BLACK _ FT440 139 Dual Power Supply Lower Housing 4 20mA Dev...

Страница 11: ...TION DIAGRAMS FT4XX Sensus Tranceiver Connections FT4XX Eqipped with Sensus Board Side View Sensus Tranceiver Red Power Clock Black Ground Green Data Red Black Green NOTE A Sensus 2m 6 ft output cable...

Страница 12: ...ry gallon of flow Note that the decimal is fixed at three places If you only have two decimal places for your K factor enter a zero for the third digit If unable to set K factor the unit is locked to...

Страница 13: ...quals Set P R UNIT SET K T UNIT SET D SET P RESET EXIT TOTAL GALLONS PRESS TO SET UNITS FOR DISPLAY R UNIT SET K T UNIT SET D SET P RESET EXIT 000 PRESS TO CHOOSE NUMBER OF DECIMAL PLACES IN TOTAL DIS...

Страница 14: ...he P A tab changes the function of the scaled pulse outputs Default is scaled pulse Any scaled pulse output can be changed to alarm high or alarm low If alarm options are selected menu tabs for settin...

Страница 15: ...se output Wrong pulse output setting Use Set P to correct pulse output setting Polarity reversed on pulse output terminals Reverse leads Display reads normally but no or incorrect 4 20mA output FT440...

Страница 16: ...roducts or parts that are typically consumed during normal operation ix Use of parts or supplies other than those sold by Seametrics which cause damage to the products or cause abnormally frequent ser...

Отзывы: