background image

2.  INTRODUCTION & SPECIFICATIONS

3. ASSEMBLY

4. OPERATION

Manufactured from corrosion resistant materials with a stainless steel motor case and noryl base cover. 

Ideal for pumping water straight from a water butt directly onto your garden. Supplied with a two piece 

aluminium swan neck extension pipe, adjustable flow control feature and snap on connector.

SPECIFICATION:

 

Model No:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WPB50A

 

Cut-out:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Automatic

 

Outlet O/D:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19mm

 

Maximum Output:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50ltr(13gal)/min

 

Maximum Head:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10mtr

 

Minimum Water Depth:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mm

 

Maximum Particle Size: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.5mm

 

Motor Power: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 350W

 Supply:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .230V

fig.1

fig.2

3.1. 

DO NOT 

connect to the mains supply until the pump is immersed in the water butt.

3.2. 

Screw the extension into the swan neck, then screw the assembly onto the outlet connector. (fig.1)

3.3. 

Clip the float switch flex into the grip on the back of the pump unit (fig.2) allowing the float switch to rise and fall freely.

3.4. 

The pump cut-off point may be altered by clipping the float switch flex to the grip fitted on the extension (fig.3), allowing the float switch  

 

to operate at a higher water level relative to the pump.

4.1. 

Place the pump unit in the water butt.

4.2. 

The pump must be installed and used in an upright position.

4.3.

 

If silt is present on the bottom of the butt, place the pump on a brick so as to lift the base of the pump clear.

 

This will protect the pump    

 

from 

ingesting 

debris. 

           

4.4. 

Connect hose pipe to the swan neck using a suitable female snap connector.

4.5. 

Connect the pump to the

 

mains power supply; provided sufficient water is present to activate the float switch, the pump will now run.

4.6. 

The output volume can be controlled by means of the flow control fitted to the snap connector. Maximum flow is achieved with the 

 

handle of the valve in line with the pipe. Flow is stopped with the handle at 90° to the pipe.

4.7. 

The float switch is provided to protect the motor from dry running and consequent overheating; it is not intended as an on/off switch.

4.8. 

If the water flow is controlled by a cut-off device fitted to the hose end, be aware that stopping the water flow will not stop the pump. No  

 

damage will accrue if the flow is stopped for short periods, but avoid prolonged running in this condition.

4.9. 

The pump is not continuously rated: 

DO NOT 

run for more than 30minutes continuously, and allow 10minutes cooling at the end of this  

 time.

5. MAINTENANCE

 

WARNING! With the exceptions listed below, all pump, float and electrical cable service maintenance and repair must only be  

 

undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate the warranty.

 

WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.

5.1.

 

Keep all parts of the pump clean. Rinse, drain and allow to dry before storing the pump. 

5.2.

 

Regularly check the inlet filter in the base of the pump to ensure that there are no blockages. To access the filter, undo the filter  

 

 

housing catch (fig.1) and remove the filter housing. Remove the circular foam filter element and wash in warm water. Replace the filter  

 

and refit the housing onto the pump inlet.   

         

 

DO NOT

 dismantle any other part of the unit.

Original Language Version

WPB50A   Issue: 1 - 20/11/13

 © Jack Sealey Limited

fig.3