background image

Maintenance 

Operations.

After Use.

Weekly.

Daily.

Monthly.

200 hrs.

Drain condensation.

check oil level.

check guards/covers.

check for oil leaks.

Replace air filter. 

check fittings. 

Inspect  Pressure  Tank.  

change pump oil.

check belt tension.

clean air filter.

check safety relief valve.

clean compressor.

check for air leaks.

check for noise or 

vibration.

5.4. RECOMMENDED OILS

 

Recommended oil for compressors:

 

- for ambient temperatures ranging from +5°c to +25°c.

 

SEALEY cPO (or equivalent) SAE 40 compressor oil.

 

 

- for ambient temperature below +5°c:

 

SAE 20 compressor oil.

Fault

Possible Cause

Remedy

Pressure drop in the tank.

Air leaks at connections.

Run  compressor  to  max.  pressure,  switch  off.                   

Brush soap solution over connections and look for 

bubbles. Tighten connections showing leaks. 

If problem persists contact Authorised Service 

Agent.

compressor does not achieve maxiumum 

pressure and overheats.

Relief valve does not open when maximum 

pressure is reached, safety valve operates.

Engine stops and does not restart.

Engine and pump run, but no air produced.

Pressure drops when compressor is idle.

Head gasket or valve fault.

Valve failure or valve incorrectly set.

Out of fuel or engine fault.

Valves leaking or head gasket damaged.

non-return valve seal defective.

contact Authorised Service Agent.

contact Authorised Service Agent.

contact Authorised Service Agent.

check fuel. If OK, contact Authorised Service Agent.

check for leaks, or contact Authorised Service 

Agent.

Empty air tank, remove the relief/non-return valve 

(fig.2 & fig.9) and clean the seat ‘D’.

If necessary replace the seal ‘E’.

6. TROUBLESHOOTING

compressor makes metallic rattle.

Bearing or piston fault.

contact Authorised Service Agent.

Safety valve operates below max pressure.

Faulty valve.

5.3.   SCHEDULED MAINTENANCE TABLE (NOT ENGINE)

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.

IMPORTANT: 

no liability is accepted for incorrect use of this product. 

WARRANTY: 

Guarantee is 12 months from purchase date, proof of which will be required for any claim. 

INFORMATION:

 For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.

01284 757500

01284 703534

[email protected]

Sole UK Distributor, Sealey Group, 

Kempson Way, Suffolk Business Park

Bury St. Edmunds, Suffolk,

IP32 7AR

www.sealey.co.uk

Web

email

Original Language Version

SA5040    Issue: 2 (SP) - 23/08/13

 

   

   Environmental Protection.

 

 

 Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and  

 

 

            packaging should be sorted, taken to a recycle centre and disposed of in a manner

                which is compatible with the environment.

 

 

 

 

When the product is no longer required, it must be disposed of in an

               environmentally protective way. 

Parts support is available for this product. To obtain a parts listing and/or diagram, please log on to www.sealey.co.uk, 

email [email protected] or phone 01284 757500.

 ©

 

Jack Sealey Limited 2013

Содержание Power PRODUCTS SA5040

Страница 1: ...structions relative to the maintenance and use of the petrol engine refer to the engine manufacturer s handbook supplied DO NOT check the ignition system by removing the spark plug or spark plug lead Use specific tester or contact service agent WARNING DO NOT touch the spark plug or plug lead whilst the engine is running severe potentially fatal electric shock may result Ensure that engine fuel is...

Страница 2: ...less than the maximum pressure the relief valve will automatically close and the tank pressure will increase back to it s maximum Note a If the relief valve does not cut in and out but is continuously closed whilst using an air appliance the capacity of the compressor may be too small for the equipment or tool b The larger gauge fig 3 2 indicates the pressure inside the tank NOT the pressure suppl...

Страница 3: ... in a very dusty atmosphere Remove the air filter element by undoing the screw fig 7 A and removing the filter cover Clean the filter by blowing through from the clean side with an air line at low pressure Replace filter cover and screw Do not operate compressor without filter as foreign bodies or dust could damage the pump WARNING Wear safety goggles when performing this task b Clean compressor c...

Страница 4: ... for leaks or Contact Authorised Service Agent Empty air tank remove the relief non return valve fig 2 fig 9 and clean the seat D If necessary replace the seal E 6 TROUBLESHOOTING Compressor makes metallic rattle Bearing or piston fault Contact Authorised Service Agent Safety valve operates below max pressure Faulty valve 5 3 Scheduled maintenance table not engine NOTE It is our policy to continua...

Отзывы: