2.  INTRODUCTION & SPECIFICATION

Fully mobile compressor powered by a Honda Gc 4.0hp petrol engine coupled to a heavy-duty, twin piston, cast iron pump. Fitted heavy-duty 

rubber transport wheels and protected by a 360° roll cage. Features twin gauges, air outlet regulator, and a 50 litre tank. 

3. PREPARATION

3.1.

 

Remove compressor from packaging and inspect for any missing parts or damage. If anything is found to be missing or damaged    

 

contact your supplier.

3.2.

 

Save the packing material for future transportation of the compressor. It is recommended to store the packing in a safe location, at 

 

least for the period of the guarantee. Then, if necessary, it will be easier to send the compressor to the service centre.

3.3. 

If not already fitted, fit the wheels and rubber feet to the compressor with the nuts, washers etc. supplied.

3.4.

 

The compressor should be located in a position that allows good air circulation around the unit and where there is good ventilation.    

 

Remember that the compressor engine produces harmful exhaust fumes.

2.1. SPECIFICATION

4.  OPERATION  

  

WARNING! Ensure that you read, understand and apply Section 1 Safety Instructions. 

4.1. STARTING
IMPORTANT! Always check and, if necessary, top-up the engine oil and the pump oil before starting. Severe engine and/or pump 

damage may otherwise result.

4.1.1.  check that the air outlet valves - one on the tank end-plate

 

(fig.1.A) and one on the regulator (fig.3.6) - are closed.

4.1.2.  Start the compressor engine, following the procedure detailed in the manufacturer’s handbook supplied.

4.1.3.  When the engine is running smoothly, the compressor will operate automatically, building up the pressure in the tank, which is shown on  

 

the pressure gauge (fig.3.2), to the maximum setting (factory set). When the maximum tank pressure is reached, the relief valve (fig.2) 

 

will automatically vent the pump output. When the tank pressure falls below the minimum threshold (approx.2 bar/29psi less  

 

 

than the maximum pressure), the relief valve will automatically close, and the tank pressure will increase back to it's maximum.

Note:

 a) 

If the relief valve does not cut in and out, but is continuously closed whilst using an air appliance, the capacity of the compressor  

 

  may be too small for the equipment or tool.

 

b) The larger gauge (fig.3.2) indicates the pressure inside the tank, nOT the pressure supplied to the air equipment. If the pressure in  

 

  the tank exceeds the relief valve maximum, a safety valve (fig.3.1) will open. 

WARNING!

 

For this reason DO NOT tamper  

 

 

  with, or adjust, the relief valve or the safety valve. 

fig.1

Model No:  . . . . . . . . . . . . . . . . . . . . . . . . . .SA5040

Motor Type

  . . . . . . . . . . . . . . Honda Gc135 Petrol

Engine Output:

. . . . . . . . . . . . . . . . . . . . . . . .4.0hp

Noise Level:

  . . . . . . . . . . . . . . . . . . . . . . . .97dB(A)

Air Displacement:

. . . . . . . . . . .10.7cfm(303ltr/min)

Maximum Free Air Delivery:

  . . .7.8cfm(220ltr/min)

Width x Depth x Height:

. . . . . 970 x 470 x 730mm

Tank Capacity:

  . . . . . . . . . . . . . . . . . . . . . . . . .50ltr

Maximum Pressure:

. . . . . . . . . . . . . .145psi/10bar

Weight:

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63kg

fig.2

fig.3

4.2. STOPPING.

4.2.1.  To stop the compressor turn the engine ignition switch (fig.4) to Off (O). See the engine manufacturer’s handbook for the complete    

 

engine shutdown procedure.

4.3. 

CONNECTING AIR POWERED EQUIPMENT.

4.3.1.  After fitting the desired coupling to the outlet valve (fig.3.6), connect the air hose and equipment.

4.3.2.  Adjust the regulator valve to the required output pressure (in accordance with the air equipment instructions) by turning the regulator   

 

knob (fig.3.4) and locking it in position with the locking ring (fig.3.5), at the required pressure (see output gauge, fig.3.3). Turn on outlet  

 

valve (fig.3.6). 

Note:

  To determine the correct working pressure and air flow requirements for any piece of equipment check the corresponding manual. Be  

 

aware that the air flow figure stated on tools and accessories refers to ‘Free Air Delivery’ and not the piston displacement of the  

 

 

compressor. When adjusting the regulator, always adjust 

up to

 the required pressure.

4.3.3.  To disconnect equipment, turn the regulator knob anti-clockwise to ‘zero’ (0) bar. Operate the equipment to depressurise the air line    

 

and then disconnect from the compressor.

Original Language Version

SA5040    Issue: 2 (SP) - 23/08/13

 ©

 

Jack Sealey Limited 2013

Содержание Power PRODUCTS SA5040

Страница 1: ...structions relative to the maintenance and use of the petrol engine refer to the engine manufacturer s handbook supplied DO NOT check the ignition system by removing the spark plug or spark plug lead Use specific tester or contact service agent WARNING DO NOT touch the spark plug or plug lead whilst the engine is running severe potentially fatal electric shock may result Ensure that engine fuel is...

Страница 2: ...less than the maximum pressure the relief valve will automatically close and the tank pressure will increase back to it s maximum Note a If the relief valve does not cut in and out but is continuously closed whilst using an air appliance the capacity of the compressor may be too small for the equipment or tool b The larger gauge fig 3 2 indicates the pressure inside the tank NOT the pressure suppl...

Страница 3: ... in a very dusty atmosphere Remove the air filter element by undoing the screw fig 7 A and removing the filter cover Clean the filter by blowing through from the clean side with an air line at low pressure Replace filter cover and screw Do not operate compressor without filter as foreign bodies or dust could damage the pump WARNING Wear safety goggles when performing this task b Clean compressor c...

Страница 4: ... for leaks or Contact Authorised Service Agent Empty air tank remove the relief non return valve fig 2 fig 9 and clean the seat D If necessary replace the seal E 6 TROUBLESHOOTING Compressor makes metallic rattle Bearing or piston fault Contact Authorised Service Agent Safety valve operates below max pressure Faulty valve 5 3 Scheduled maintenance table not engine NOTE It is our policy to continua...

Отзывы: