background image

IMPORTANT

BEFORE  USING  THIS  PRODUCT,  PLEASE  READ  THE  INSTRUCTIONS  CAREFULLY.  MAKE  CAREFUL  NOTE  OF  SAFETY  INSTRUCTIONS, 

WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE

AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE.

  1.  SAFETY INSTRUCTIONS

1.1. 

ELECTRICAL SAFETY

 

WARNING!

 It is the user’s responsibility to read, understand and comply with the following:

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and all electrical 

connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual 

Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD (Residual Current Device) is used with all 

electrical products. It is particularly important to use an RCD together with portable products that are plugged into an electrical supply not protected by an RCCB. 

If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer. You must also read and understand the 

following instructions concerning electrical safety. 

1.1.1 

The 

Electricity At Work Act 1989

 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using  

 

a Portable Appliance Tester (PAT), at least once a year. 

1.1.2 

The 

Health & Safety at Work Act 1974

 makes owners of electrical appliances responsible for the safe condition of the appliance, and the safety of the

 

appliance operator.

 If in any doubt about electrical safety, contact a qualified electrician.

 

1.1.3 

Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. 

 

See 1.1.1. & 1.1.2. above and use a Portable Appliance Tester (PAT).

1.1.4 

Ensure that cables are always protected against short circuit and overload.

1.1.5 

Regularly inspect power supply leads, plugs and all electrical connections for wear and damage and especially 

 

power connections, to ensure that none is loose. 

1.1.6 

Important:

 Ensure the voltage marked on the product is the same as the electrical power supply to be   

 

used and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse    

 

smaller than 13 amps for certain products, see fuse rating at right. 

1.1.7 

DO NOT pull or carry the powered appliance by its power supply lead. 

1.1.8 

DO NOT pull power plugs from sockets by the power cable.

1.1.9 

DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

 

a qualified electrician. A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off 

 

and fit a new plug according to the following instructions (discard old plug safely).

 

(UK only - see diagram at right). 

Ensure the unit is correctly earthed via a three-pin plug.

 

 

a) 

Connect the green/yellow earth wire to the earth terminal ‘E’.

 

b) 

Connect the brown live wire to live terminal ‘L’.

 

c) 

Connect the blue neutral wire to the neutral terminal ‘N’.

 

d) 

After wiring, check that there are no bare wires, that all wires have been correctly connected, 

 

 

that the cable external insulation extends beyond the cable restraint and that the restraint is tight.

1.1.10 

Some products require more than a 13 amp electrical supply. In such a case, NO plug will be fitted. You must contact a qualified electrician to ensure   

 

that a 30 amp fused supply is available. We recommend you discuss the installation of a industrial round pin plug and socket with your electrician. 

 

1.1.11 

Cable extension reels. When a cable extension reel is used it should be fully unwound before connection. A cable reel with an RCD fitted is recommended 

 

since any product which is plugged into the cable reel will be protected. The section of the cable on the cable reel is important and should be at least   

 

1.5mm², but to be absolutely sure that the capacity of the cable is suitable for this product and for others that may be used in the other output sockets,  

 

we recommend the use of 2.5mm² section cable.

 

  

WARNING! Be very cautious if using a generator to power the welder. The generator must be self-regulating and stable with regard to voltage,    

 

wave form and frequency. The output must be greater than the power consumption of the welder. If any of these requirements is not met the  

 

electronics within the welder may be affected.

 

NOTE: The use of an unregulated generator may be dangerous and will invalidate the warranty on the welder.

   

WARNING! The welder may produce voltage surges in the mains supply which can damage other sensitive equipment (e.g. computers). To   

 

prevent this happening, it is recommended that the welder is connected to a power supply that does not feed any sensitive equipment.

Blue 

Neutral 

Wire

Yellow & Green 

Earth Wire 

Cable 

Restraint

FUSE RATING

13 AMP

Brown

Live 

Wire

1.2  

  GENERAL SAFETY

  DANGER! Unplug the welder from the mains power supply before performing maintenance or service.

 

OPERATORS MUST RECEIVE ADEqUATE TRAINING BEFORE USING THE WELDER. 

 

Keep the welder and cables in good working order and condition. 

Take immediate action to repair or replace damaged parts.

 

Use genuine parts and accessories only. 

Unapproved parts may be dangerous and will invalidate the warranty.

 

 

Use an air hose to regularly blow out any dirt from the liner and keep the welder clean for best and safest performance.

 

Check and spray the gas cup and contact tip regularly with anti-spatter spray, available from your Sealey dealer. 

 

Locate welder in a suitable work area. Ensure that the area has adequate ventilation as welding fumes are harmful.

 

Keep work area clean, tidy and free from unrelated materials. Also ensure the working area has adequate lighting and that a fire extinguisher is at hand.

  

WARNING! Use welding head shield to protect eyes and avoid exposing skin to ultraviolet rays given off by electric arc. Wear safety welding gauntlets. 

  

Remove ill fitting clothing, remove ties, watches, rings and other loose jewellery and contain long hair.

 

Ensure the workpiece is correctly secured before welding.

 

Avoid unintentional contact with the workpiece. Accidental or uncontrolled use of the torch may be dangerous and will wear the nozzle. 

 

Keep unauthorised persons away from the work area. Any persons working within the area must wear a protective head shield and gloves.

 

Stand correctly keeping a good footing and balance, ensure the floor is not slippery and wear non-slip shoes.

 

DO NOT operate the welder if it or the cables are damaged and DO NOT attempt to fit any unapproved torches or other components to the welder.

 

DO NOT get welder wet or use in damp or wet locations or areas where there is condensation.

  

DANGER! DO NOT weld near flammable solids, liquids or gases and

 

DO NOT weld containers or pipes which have held flammable materials.    

  Avoid welding materials which have been cleaned with chlorinated solvents or welding near such solvents.

 

DO NOT stand welder on a metal workbench, car bodywork or similar.

 

DO NOT touch any live metal parts of the torch or electrode while the machine is switched on.

 

DO NOT pull the welder by the cable, or the torch. Protect cables from sharp or abrasive items, DO NOT bend, strain or stand on cables or leads. Protect from  

 

heat. Long lengths of slack must be gathered and neatly coiled. DO NOT place cables where they endanger others.

 

DO NOT touch the torch or workpiece immediately after welding as they will be very hot. Allow to cool. 

 

DO NOT operate welder while under the influence of drugs, alcohol or intoxicating medication, or if tired.

  

When not in use store the welder in a safe, dry, childproof area.

INSTRUCTIONS FOR: 

GAS/NO GAS MIG WELDER

MODEL NO: 

MIGHTYMIG150

Thank  you  for  purchasing  a  Sealey  product.  Manufactured  to  a  high  standard  this  product  will,  if  used  according  to  these  instructions 

and properly maintained, give you years of trouble free performance.

Original Language Version

MIGHTYMIG150    Issue: 2 - 26/02/10

Содержание MIGHTYMIG 150

Страница 1: ...INSTRUCTIONS FOR MIG WELDER MODEL NO MIGHTYMIG 150 Original Language Version MIGHTYMIG150 Issue 2 26 02 10 ...

Страница 2: ...he cable reel is important and should be at least 1 5mm but to be absolutely sure that the capacity of the cable is suitable for this product and for others that may be used in the other output sockets we recommend the use of 2 5mm section cable WARNING Be very cautious if using a generator to power the welder The generator must be self regulating and stable with regard to voltage wave form and fr...

Страница 3: ...efore use Avoid getting gas cylinders oily or greasy DO NOT lift a cylinder by the cap guard or valve Always keep caps and guards in place and close valve when not in use fig 3 fig 4 3 1 Assembly of wheels See fig 2 3 1 1 Drop the axle brackets 7 through the slots in the rear of the bottom tray 6 3 1 2 Attach a circlip 9 to one end of the axle 10 and slide a wheel 8 onto the axle and right up to t...

Страница 4: ...he weld area must also be free of paint rust grease etc b Obtain the best connection by grinding the point of contact on the workpiece before connecting the clamp 6 3 If welding a vehicle disconnect the battery or fit a Electronic Circuit Protector available from your Sealey dealer 6 5 Set up the current switches to give the required power setting and adjust the wire speed accordingly 6 6 During t...

Страница 5: ...d by casing 6 Output U0 Rated maximum and minimum no load voltage I2 U2 Current and corresponding voltage X Welding ratio based on a 10 minute cycle 20 indicates 2 minutes welding and 8 minutes rest 100 indicates continuous welding 8 Welding current range 7 Mains Supply U1 Rated supply voltage and frequency Imax Maximum current I1eff Maximum effective current 9 Serial Number Specifically identifie...

Страница 6: ...ll the liner from the torch cable 9 6 7 Insert the new liner into the torch cable and secure it in the wire drive unit by replacing the torch cable clamp See fig 14 Insert the other end of the liner through the locking ring and fully into the torch control assembly 9 6 8 Ensure that the switch moulding fig 16 3 is fully seated down into the lower moulding 4 Place the torch head assembly 2 down int...

Страница 7: ...oo far from or at wrong angle to work The distance from gas cup to workpiece should be 8 to 10mm Gas leak Check hoses connections and torch assembly Press the gas cup into correct position Faulty Electrovalve Clean out or replace 9 Electrode sticking in gas cup nozzle Worn or defective gas cup nozzle Replace gas cup nozzle Section 4 1 8 to 4 1 11 Electrode deformed Check roller tension Section 3 1...

Страница 8: ...ective 2000 14 EC Outdoor Noise Emissions Directive 2006 95 EC Low Voltage Directive 2002 96 EC WEEE Directive 2004 108 EC EMC Directive 2002 95 EC RoHS Directive 93 68 EEC CE Marking Directive 97 23 EC Pressure Equipment Directive And the following harmonised standard s Additional technical standards and specifications if applicable Technical file compiled by Jack Sealey Ltd Signed Date Place Bur...

Страница 9: ...RACKET 8 M MIG150 08 CLAMP 9 M MIG150 09 AXLE 10 M MIG150 10 WIRE FEED UNIT 11 M MIG150 11 WIRE FEED ROLLER 12 M MIG150 12 SIDE PANEL A 13 M MIG150 13 POWER CORD 14 M MIG150 14 EARTH CABLE WITH CLAMP 15 M MIG150 15 WELDING TORCH 16 M MIG150 16 COVER 17 M MIG150 17 WIRE SPEED KNOB 18 M MIG150 18 SWITCH 19 M MIG150 19 OVERLOAD INDICATOR 20 M MIG150 20 CABLE NIB 21 M MIG150 21 FRONT PANEL ITEM PART N...

Отзывы: