background image

5.5.   

ALTERING CORRECTION FACTOR INDIRECTLY

5.5.1.

  

Wait for meter to go to standby (fig.10).

5.5.2.

  

Reset the total (5.2.4) fig.11 to zero.

5.5.3.  

Dispense into measuring container (minimum 5 litres) and record.

5.5.4.

If displayed value does not match actual measured value
press and hold MOVE key until each digit reads as per the 
measured value. Press MOVE key to visit each digit in turn.

5.5.5.  

Once value is correct (i.e. matches measured value) press and 

 

hold MOVE key until Cal mode quits (fig.11).

6.

MAINTENANCE

6.1.   

CHANGING THE BATTERY

6.2.

Battery type: Lithium CR2 3V 1400mAh.

6.2.1.

Remove the rubber protective cover from the meter.

6.2.2.

Remove the screw and cover from the side of the meter.  

6.2.3.

  

Remove and replace battery (fig.14).

6.2.4.

Replace cover and secure with screw.

6.2.5.

Replace the protective rubber cover.

6.3.

Check the unit connections before each use.

6.4.

Check the nozzle valve for leaks, if it does not seal, replace before using.

6.4.

   Drain air regulator water trap daily.

6.5.

Top up lubricator as required, using a quality air tool oil.

6.6.

 

  To change the silencer, remove the circlip (fig.15) and remove the old silencer, place a new silencer into the recess and refit the circlip.

 

 NOTE:

For any other maintenance and repairs the unit should be returned to your Sealey dealer.

Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR

 01284 757500 

 01284 703534 

 [email protected] 

 www.sealey.co.uk

ENVIRONMENT PROTECTION

Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to 
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely 
unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and dispose of the product and fluids
according to local regulations.

Note

: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior 

notice.

Important

: No Liability is accepted for incorrect use of this product.

Warranty

: Guarantee is 12 months from purchase date, proof of which is required for any claim.

Original Language Version

© Jack Sealey Limited

fig.13

WEEE REGULATIONS

Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment 
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid 
waste authority for recycling information.

BATTERY REMOVAL SEE SECTION 6

Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products 
containing batteries (as defined within these regulations), that they are registered with Valpak’s registered compliance scheme. Jack 
Sealey Ltd Batteries Producer Registration Number (BPRN) is BPRN00705.

AK4562D  Issue 3 (H, 5, F)  24/09/18

fig.12

fig.14

fig.15

Содержание AK4562

Страница 1: ...nnect air pressure from equipment when not in use 8 DO NOT exceed the maximum air pressure of 115psi 8 DO NOT point the nozzle at people or animals 8 DO NOT use the equipment near open flames 8 DO NOT smoke whilst using this equipment 8 DO NOT use to extract corrosive fluids 8 DO NOT dismantle tamper with or adapt the pump for any purpose other than for which it is designed 8 DO NOT use the unit i...

Страница 2: ...the base plate and secure using four bolts washers and nuts not shown in fig 1 4 2 PUMP AND AIR REGULATOR LUBRICATOR ASSEMBLY 4 2 1 Apply a small amount of liquid thread sealant onto the threads of the air inlet of the pump and attach the air regulator lubricator fig 2 WARNING DO NOT allow thread sealant to enter the pump 4 2 2 Attach the outlet pipe to the male outlet thread on the pump and attac...

Страница 3: ...urrent total resets to 0 00 5 2 5 To display correction factor and Total fig 8 Hold MOVE and RESET for 3 seconds Value 1 4000 is correction factor 1234567 overall total 5 2 6 To change Units fig 9 Hold MOVE and RESET for several seconds Area 2 in fig 5 shows units Press RESET to change units Press and hold MOVE to confirm choice 5 3 DETERMINING THE CORRECTION FACTOR 5 3 1 Dispense at least 1 litre...

Страница 4: ...es sealey co uk www sealey co uk ENVIRONMENT PROTECTION Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycling centre and disposed of in a manner which is compatible with the environment When the product becomes completely unserviceable and requires disposal drain any fluids if applicable into approved containers a...

Отзывы: