16
DAT Autoloader Installation Manual
4. Installing the external autoloader
Configuring the external autoloader
This section describes how to configure the SCSI ID used by
the external autoloader. Additional drive options are
configured at the factory as follows:
•
MRS checking is enabled.
•
Parity checking is enabled.
•
Data compression is enabled.
•
Power-on self-test diagnostics are enabled.
➤
Note. To change these and other advanced drive
options, you must remove the external autoloader from
its case. Then set the appropriate jumpers as described
in the previous chapter.
Setting the SCSI ID
The external autoloader must be set to use a SCSI ID that is
not being used by any other SCSI device attached to the
same SCSI controller. The SCSI ID on the external
autoloader is shown in a small window on the back of the
drive, as shown in Figure 8 on the following page.
➤
Note. SCSI ID 7 is often used by the SCSI controller. In
some systems, SCSI ID 0 may be used by the bootable
hard drive.
Содержание Scorpion 96
Страница 2: ...Scorpion 96 DAT Autoloader Installation Manual...
Страница 7: ......