Byte 3
The
block descriptor length is the number of bytes in the
block descriptor. This value does not include the page
headers and mode pages that follow the block descriptor,
if any.
Byte 4
The
density code is not supported.
Bytes 5–7
The
number of blocks field contains the total number of
blocks available to the user.
Byte 8
Reserved
Bytes 9–11
The
block length specifies the number of bytes contained
in each logical block described by the block descriptor.
3.4.14 Start/Stop Unit command (1B
H
)
When the drive receives the Start/Stop Unit command, the drive either
spins up or spins down, depending on the setting of the start bit in byte 4.
If the host adapter supports disconnection, the drive disconnects when
it receives the Start/Stop Unit command and reconnects when it is up to
speed and ready.
Bytes
Bits
7
6
5
4
3
2
1
0
0
0
0
0
1
1
0
1
1
1
LUN = 0
0
0
0
0
Immed
2
0
0
0
0
0
0
0
0
3
0
0
0
0
0
0
0
0
4
0
0
0
0
0
0
0
Start
5
0
0
0
0
0
0
0
0
Byte 1 If the
immediate (Immed) bit is 0, the drive returns the status after
the command is completed. If the Immed bit is 1, the drive returns
the status when it receives the command.
Byte 4 If the
start bit is 1, the drive spins up. If the start bit is 0, the drive
spins down.
56
Medalist Pro 2160N/2160WC Product Manual, Rev. A
Содержание Medalist 2160N (ST52160N)
Страница 2: ......
Страница 10: ......
Страница 26: ...16 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 44: ...34 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 96: ...86 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 100: ...90 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 126: ...116 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......