Error code (hex)
Description
Byte 12
Byte 13
19
02
Error in PList
19
03
Error in GList
1A
00
A parameter overrun occurred.
1C
00
The defect list could not be found.
1C
01
The primary defect list could not be found.
1C
02
GList not found
1D
00
A miscompare occurred during a verify
operation.
20
00
The drive received an invalid command
operation code.
21
00
The logical block address was not within the
acceptable range.
24
00
The drive received a CDB that contains an
invalid bit.
25
00
The drive received an invalid LUN.
26
00
The drive received an invalid field in the
Parameter List.
26
01
CDB with unsupported parameter
26
02
CDB with invalid parameter
26
03
CDB with unsupported threshold parameter
29
00
A power-on reset or a bus device reset
occurred.
2A
00
Parameter changed by another initiator
2A
01
The Mode Select parameters were changed
by another initiator.
2A
02
Log parameters changed
2F
00
Commands cleared by another initiator
31
00
Medium format corrupted
32
00
No spare defect locations available.
39
00
Saved pages not found
3F
01
The firmware/microcode was changed.
Medalist Pro 2160N/2160WC Product Manual, Rev. A
95
Содержание Medalist 2160N (ST52160N)
Страница 2: ......
Страница 10: ......
Страница 26: ...16 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 44: ...34 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 96: ...86 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 100: ...90 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 126: ...116 Medalist Pro 2160N 2160WC Product Manual Rev A...
Страница 134: ......
Страница 135: ......
Страница 136: ......
Страница 137: ......