1.9
Environmental specifications
1.9.1
Ambient temperature
Operating
5
°
to 55
°
C (41
°
to 131
°
F)
Nonoperating
--40
°
to 70
°
C (--40
°
to 158
°
F)
1.9.2
Temperature gradient
Operating
20
°
C per hour (36
°
F per hour)
Nonoperating
25
°
C per hour (45
°
F per hour)
1.9.3
Altitude
Operating
--1,000 to 10,000 ft (--305 to 3,048 m)
Nonoperating
--1,000 to 40,000 ft (--305 to 12,192 m)
1.9.4
Relative humidity
Operating
8% to 80% noncondensing
Maximum wet bulb 29.4
°
C (84.9
°
F)
Maximum operating
gradient
10% per hour
Nonoperating
5% to 95% noncondensing
Maximum wet bulb 35.0
°
C (95.0
°
F)
1.9.5
Shock and vibration
Mount the drive for normal operation as recommended in Section 2.4 on
page 23. Shock and vibration may be applied in the X, Y or Z axis.
Episodes are not repeated more than twice per second.
The shock and vibration limits specified in this document are measured
directly on the chassis. If the drive is installed in an enclosure to which
the shock or vibration is applied, the resonances within the enclosure
may not subject the drive to movement that exceeds the specification
limits. The enclosure must be modified to ensure that the drive movement
complies with the specification.
12
Medalist 1640 and 2140 Product Manual, January 1996
Содержание Medalist 1640
Страница 1: ...Medalist Family Medalist 1640 Medalist 2140 ATA Interface Drives Product Manual...
Страница 2: ......
Страница 3: ...Medalist Family Medalist 1640 Medalist 2140 ATA Interface Drives Product Manual...
Страница 8: ......
Страница 28: ...Figure 4 Configuration settings 20 Medalist 1640 and 2140 Product Manual January 1996...
Страница 34: ...Figure 7 ATA interface connector pin assignments 26 Medalist 1640 and 2140 Product Manual January 1996...
Страница 46: ......
Страница 47: ......