When using IORDY, the drive operates at programmed timing specifica-
tions, as shown below.
Time
Description
Min
Max
T0
Cycle time
120 nsec
----
T1
Address valid until IOCS16-- is asserted
----
20 nsec
T2
Drive address (CS1FX--, CS3FX--,
DA0, DA1 and DA2) valid before DIOR--
or DIOW-- setup
25 nsec
----
T3
IORDY setup time
----
25 nsec
T4
DIOW-- or DIOR-- pulse width (8-bit)
70 nsec
----
DIOW-- or DIOR-- pulse width (16-bit)
70 nsec
----
T5
IORDY pulse width
----
1,250
nsec
T6
DIOW-- data setup
20 nsec
----
T7
DIOR-- data setup
20 nsec
----
T8
DIOR-- data hold
5 nsec
----
T9
DIOW-- data hold
10 nsec
----
T10
DIOW-- or DIOR-- to address valid hold
5 nsec
----
T11
Address invalid until IOCS16-- is
negated
----
5 nsec
Figure 9. Programmed I/O timing with IORDY
36
Medalist 1640 and 2140 Product Manual, January 1996