SD-MA-025
20
The default IP address for SWM controller is
192.168.0.247
Users need to change the IP address of the
control PC to the same network segment as the SWM.
•
Change the
‘Obtain an IP address automatically’
to
‘Use the following IP address’
to set up a
static
IP address of
TCP/IPv4
in
Ethernet Properties
➢
IP address: any address between
192.168.0.2
and
192.168.0.254
except the address which has been
taken by the SWM
➢
Subnet mask:
255.255.255.0,
Default Gateway:
192.168.0.1
•
Once the control PC IP address having been set up, connect PC to the RJ45 ports of SWM
controllers via a network cable and then press the
Connect
button to connect the device.
4.4.2
Directly connect via Ethernet cable
Operation steps are as follows:
1.
Connect the PC and device directly via an Ethernet cable
2.
Manually setting up the IP address of the PC, and the IP address of the PC and the device should be
in a same network segment (The default IP address of the device is 192.168.0.247, and the default
network mask of the device is 255.255.255.0).
3.
Run the PC control software
(If the IP address of the PC changed after running the software, you
should close it and run it again)
4.
Click to switch ‘Ctrl Mode’ to ‘Network’
5.
Click the ‘Search Device’ button
6.
Click the device you want to control in the result list (When you click it, the software will read
automatically the network configuration such as network port of the device)
7.
Click the ‘Disconnected’ button (which is right to ‘Status’) to connect to the
device
8.
After con
nected successfully, the button right to ‘Status’ will be ‘Connected’ (
If you click it now, it will
disconnect from the device)
Note
:
A.
The
default IP address is 192.168.0.247
,
and the default subnet mask is 255.255.255.0
B.
How to query the IP address of the device, please refer to
4.3.2 Query IP info via UART
and
4.4.4
Query IP info via network
C.
How to set up IP address on Windows OS, please refer to
4.4.1 Set IP address