SD-MA-025
SWM Seamless Modular Matrix Switchers
User Manual
Document No.
Document Version: 03
Страница 1: ...SD MA 025 SWM Seamless Modular Matrix Switchers User Manual Document No SD MA 025 Document Version 03 ...
Страница 2: ...6 3 2 Communication port and connection method 7 3 2 1 RS232 control and connection 8 3 2 2 Ethernet control and connection 8 3 3 Front panel SWM16 for example 8 3 4 Operating SWM Matrix via front panel 9 3 5 About DVI U daughter card 10 4 PC tool user guide SWM16 for example 11 4 1 Account s authentication 11 4 1 1 Password modification 11 4 2 PC tool s UI 12 4 2 1 UI Style 12 4 2 3 Custom Name 1...
Страница 3: ... info via network 23 4 4 5 Set IP info via network 24 4 4 6 Troubleshoot 25 4 5 Route switch of Matrix UI style 26 4 5 1 Route switch of other UI styles 26 4 5 2 Other route switch 28 4 5 3 System reset 29 4 6 Advanced route switch 29 4 7 Signal Setting 31 4 8 PQ Position 32 4 9 OSD Setup 33 4 9 1 Set OSD Content 33 4 9 2 OSD detail settings 35 4 9 3 Export OSD Settings 37 4 9 4 Import OSD Setting...
Страница 4: ...SD MA 025 4 10 Video Wall 38 4 11 EDID Control 40 5 Web control 41 6 Commands for serial port control 43 7 Remote control IR 47 8 Using Cautions 48 ...
Страница 5: ...ghter card support HDMI DVI VGA YPbPr CVBS signal with different terminal adapters So for HDMI signal we can use HDMI daughter card directly or DVI U daughter card for VGA signal we can use VGA DB15 interface daughter card directly or DVI U daughter card There are additional HDMI and UHD HDMI bypass input and output cards for selection which have no seamless switching function Seamless switching a...
Страница 6: ...5 1080p30 HDBaseT RJ45 800x600 1024x768 1280x768 1280x800 1280x1024 1360x768 1400x1050 1600x1200 1920x1080 UHD HDMI HDMI A HDMI2 0 Output Interface type Fibre HDBaseT HDMI DVI 3G HD SD SDI VGA YPbPr CVBS Signal interface and standard HDMI DVI U HDMI A HDMI V1 3A 1024x768 1280x1024 1360x768 1280x720 1600x1200 1920x1080 1680x1050 DVI DVI U DVI 1 0 1024x768 1280x1024 1360x768 1280x720 1600x1200 1920x...
Страница 7: ...Dual AC power interface can be connected at the same time or only connect one of them Power1 is the main power interface and the Power2 is the auxiliary power interface The two power has the same capacity 2 There is one spare fuse in each power switch 3 SWM series peripheral device connection SWM16 for example 3 1 Input and output 1 SWM16 can be configured up to 8 input cards 8 output cards each c...
Страница 8: ... cards HDMI card HDMI non seamless cards UHD HDMI card DVI U card SDI card HDBaseT card VGA card Output cards HDMI card HDMI non seamless card UHD HDMI card DVI U card SDI card HDBaseT card VGA card 3 2 Communication port and connection method RS 232 straight cable baud rate 9600 DB9 connector Pin description as bellow Index Pin 1 N u 2 Tx Matrix PC 3 Rx Matrix PC 4 N u 5 Gnd 6 N u 7 N u 8 N u 9 N...
Страница 9: ...SD MA 025 3 2 1 RS232 control and connection Baud rate 9600 3 2 2 Ethernet control and connection Note Factory default network setting 3 3 Front panel SWM16 for example 1 2 3 4 5 ...
Страница 10: ...urrent route To check which input is currently connected with chosen output simply press correct output key and look which inputs button comes up Example OUT 1 pressed IN 2 lit up means the output 1 current input is input 2 2 Change route Select output key from outputs key after it lit up choose an input source you would like to appear on that output after lit up press enter Example OUT 1 IN 1 ENT...
Страница 11: ...presents saved mode number press enter Example RECALL OUT 1 ENTER route saved as a mode 1 is on the screens 3 5 About DVI U daughter card DVI U daughter card support CVBS YPbPr VGA DVI HDMI signal User can select the exact signal by PC Tool refer to chapter 4 8 Signal Setting User need use different adapter to meet different signal for example when YPbPr in user need use YPbPr DVI adapter Note YPb...
Страница 12: ...t password of Administrator access to all features 111111 Default password of User access to all features except OSD function 000000 4 1 1 Password modification 1 Click drop down list to select account Administrator or User 2 Input current password then click the modify button to authenticate Input new password twice then click the modify button ...
Страница 13: ...D MA 025 4 2 PC tool s UI The PC tool s UI is as follows 4 2 1 UI Style There are totally 5 styles you can switch by clicking Switch UI button Matrix Style Default style of small size device SWM08 SWM16 ...
Страница 14: ...SD MA 025 Icon Style Default style of large size device SWM36 SWM80 Text Style ...
Страница 15: ...SD MA 025 Custom Name Style Text and Custom Name Mixed Style NOTE The last two style only occurs after you set up the custom name of the input or output ...
Страница 16: ...put or output that you want to modify then input the custom name Other UI Style On Matrix Switch Page 1 Click the input or output that you want to modify 2 Input custom name 3 Click the modify button Note It will delete a current input and restore to the last modification when you click the Restore button next to the Modify button ...
Страница 17: ...erial port cable 2 Run the PC control software If already run click to switch to the Matrix Switch page 3 Click to switch Ctrl Mode to UART 4 Click the drop down list which is right to the Port then select the correct COM port There may be some COM ports connected to the PC 5 Click the Disconnected button which is right to Status to connect to the device 6 After connected successfully the button r...
Страница 18: ...en it will be updated automatically If there s no COM port showing please make sure the driver is installed correctly and then reboot your PC and try again 3 If the button which is right to the combo box shows Connected and the software showing a message of device response timeout please check the COM port whether is correct the cable whether is connected properly or the device whether is powered ...
Страница 19: ...e device via UART Click the Find via UART button in Network Setting tab to read the IP information 4 3 3 Set IP info via UART After connecting to the device via UART switch to Network Setting tab 1 Click Find via UART button to read IP information 2 Modify IP address type to Static IP or Auto IP DHCP If IP address type modified to Static IP then input IP address subnet mask and gateway information...
Страница 20: ...MA 025 3 Click Save Config button to save 4 Click Find via UART button again to read IP information to make sure the modification is successful 4 4 Control via network 4 4 1 Set IP address on Windows 1 2 3 ...
Страница 21: ...PC and the device should be in a same network segment The default IP address of the device is 192 168 0 247 and the default network mask of the device is 255 255 255 0 3 Run the PC control software If the IP address of the PC changed after running the software you should close it and run it again 4 Click to switch Ctrl Mode to Network 5 Click the Search Device button 6 Click the device you want to...
Страница 22: ...nd device connected to should support HDCP function 3 Run the PC control software If the IP address of the PC changed after running the software you should close it and run it again 4 Click to switch Ctrl Mode to Network 5 Click the Search Device button 6 Click the device you want to control in the result list When you click it the software will read the network configuration such as network port ...
Страница 23: ... a valid IP address and this will cause device not to be found B If the device can be found but not able to connect successfully please make sure the IP address of the PC and the device are in a same network segment e g when subnet mask is 255 255 255 0 then 192 168 0 2 and 192 168 0 3 are in a same network segment The UI after connected successfully will be as follows ...
Страница 24: ... information as follows Method A Switch to Matrix Switch page then click Search Device button to query IP address information Method B After switching to Network Setting page click Search Device button to search devices then click one device in the result list to load its IP address information 1 2 ...
Страница 25: ...e software shows a message of Succeeded click Search Device button to load configuration again to make sure your modification is saved successfully NOTE 1 When selecting the device it will display the matrix s network board information User can edit the device s name in order to better identify matrix User can set dynamic IP static IP subnet mask gateway and another network information At the same...
Страница 26: ...in a same network segment Or when using connection via LAN connect the PC and the device to a same network router which support HDCP function 2 The software shows a message of device response timeout after connected to the device Cause A The IP address of the PC and the device are not in a same network segment Solution A Make sure the IP addresses are in a same network segment 3 The software shows...
Страница 27: ...and the output ports The UI of PC tool will show the device channel route Users can switch and assign different inputs to the selected outputs in the matrix by selecting a correct grid View output ports input ports 4 5 1 Route switch of other UI styles 1 To change route click one input port red border green background then the output port s background turns green next select Switch Port status wil...
Страница 28: ...d and its background will turn green 2 After mouse cursor moving to an input port or an output port its text will turn red and its background will turn blue 3 Clicking or moving mouse cursor to an output input port we can find its input output port accordingly to background colour change ...
Страница 29: ...own list then click one input to switch it to all output ports 2 Recall mode recall a mode previously saved Click the drop down list then select one mode to load saved route in this mode 3 Save mode save current input and output route in a mode Click the drop down list then select a mode number to save ...
Страница 30: ...or cancel operation 4 6 Advanced route switch To facilitate the demonstration functions SWM supports periodic switching of selected inputs on chosen outputs Operation guide is as follows 1 Click the output port to assign input s Also can press Ctrl or Shift first then click to select more output ports 2 Press Ctrl or Shift first then select input ports ...
Страница 31: ...igure automatically switch Switch frequency default 2000ms All outputs send combine unchecked Switch all output ports one by one checked Switch all output ports at the same time NOTE Switch one input one by one if there re many input ports selected Wait others finished start a next loop Only can be set when All outputs send combined is checked ...
Страница 32: ...l other outputs finish theirs current switching loop Send cmd only one loop stop automatically switch when a loop is finished Select all outputs Tick all output ports 6 Click Start button to start looping 7 Click Stop button to stop looping 4 7 Signal Setting 1 Read and set the type of all input ports DVI VGA YPbPr CVBS corresponding to the actual input terminal type HDMI DVI VGA YPbPr CVBS Note O...
Страница 33: ...terminal type according to the type of terminal that connected to the display device HDMI DVI VGA YPbPr CVBS Note Only the DVI U output board has this setting SDI HDBaseT fibre and other output boards this setting is invalid 6 Read and set the output board s output resolution 4 8 PQ Position User can read and set the brightness contrast saturation sharpness of the input board output board also can...
Страница 34: ... the characters by the drop down menu of the Board Address currently only supports the font overlay on the output board 2 Set Text mode Normal 3x3 3x4 A Normal Display Normally B 3x3 Input 8 lines text as a unit then repeat display this unit 3 lines and 3 columns totally repeat display 9 times C 3x4 Input 8 lines text as a unit then repeat display this unit 3 lines and 4 columns totally repeat dis...
Страница 35: ...SD MA 025 4 Self Clocking if this is checked it will display date and time and update automatically 5 Click Set button under the edit box to set OSD ...
Страница 36: ... 2 Set transparent of OSD background 3 Set alpha of OSD A Drag to choose the alpha value B Click Set button to set alpha of OSD 4 Set the text colour or the background colour A Click the colour button to set Default 5 colour Red Green Blue White Black B Use customer colour First Click the Combobox and select one default colour to edit Then choose the colour you want in the Colour window ...
Страница 37: ... the text font type the font size 7 Read OSD information of one channel A Click the drop down list which is right to the text board address to select channel number B Click Read button which is under the edit box to read OSD information 8 Update Device Time If Self Clocking function is enabled click Update button to update PC s current time to device 1 2 3 4 ...
Страница 38: ... OSD Settings 1 Click Import button 2 Choose OSD setting file which exported before 3 Click Open to import 4 9 5 OSD mode Click drop down list to select a mode then click Save or Load button to save or load an OSD mode 4 9 6 Reset OSD 1 Click drop down list which is right to Board Address to select a channel 2 Click Reset button to reset this channel s OSD setting ...
Страница 39: ...lay to display Input 1 Input 8 Output Select Set the output port that connect to the display need according to the Video wall system setup status to set Output 1 Output 8 It means which output port connect to the display Output Type Set the terminal type of the output port need to set according to the Video wall system setup status When in splicing mode can only support HDMI Output Format Set the ...
Страница 40: ...e Video wall system setup status to set Output 1 Output 8 It means which output port connect to the display Output Type Set the terminal type of the output port need to set according to the Video wall system setup status When in merging mode can only support HDMI Output Format Set the output port output resolution When in merging mode can only support 1080P 60HZ Horizontal adjust Set the Video wal...
Страница 41: ...e output port then click the Read button to read EDID 2 Write EDID First read an EDID from output port or open a EDID file that saved before then input the input port then click the Write button to write EDID 3 Save EDID After reading EDID successfully click Save button then choose the save path and file name for saving EDID ...
Страница 42: ...e NOTE The computer IP and matrix IP must be in the same segment and the same local area network For example the matrix s IP is 192 168 1 xxx then the computer IP must be 192 168 1 yyy Otherwise need to change the matrix s IP or the computer s IP Note the browser must support HTML5 feature which must be IE10 and above 2 Condition know the matrix IP address Input the IP on the web browser then ente...
Страница 43: ... set all outputs on one input save layouts and recall them as well as reset the device 1 switch language to Chinese to switch back to English click again 2 Read an input signal type 3 Read an output change the type and set a format 4 Type in serial commands Another UI style you can choose by clicking Switch UI To go back to 1st UI click Switch UI ...
Страница 44: ...gth Command Body Check Sum Command Tail Example 1 7B 7B 01 02 01 01 F5 7D 7D CMD Head 7B 7B doesn t change CMD Index 01 different type of command has different index CMD length 02 represents the length of the command body CMD Body 01 01 different value for specific modes in each command CMD Check Sum F5 depends of the sum of CMD Index CMD length CMD Body CMD Tail 7D 7D doesn t change ...
Страница 45: ...B 7B 01 02 01 00 F4 7D 7D IN port 2 to OUT port 1 7B 7B 01 02 06 01 FA 7D 7D IN port 7 to OUT port 2 7B 7B 01 02 06 02 FB 7D 7D IN port 7 to OUT port 3 7B 7B 01 02 07 07 01 7D 7D IN port 8 to OUT port 8 Examples for units with up to 8 input and 8 output ports 7B 7B 01 02 00 01 F4 7D 7D IN port 1 to OUT port 1 7B 7B 01 02 00 02 F5 7D 7D IN port 1 to OUT port 2 7B 7B 01 02 00 04 F7 7D 7D IN port 1 t...
Страница 46: ...Mode Save Format 7B 7B 02 01 save as mode F check sum 7D 7D Examples 7B 7B 02 01 00 F3 7D 7D save as mode 1 7B 7B 02 01 01 F4 7D 7D save as mode 2 7B 7B 02 01 02 F5 7D 7D save as mode 3 7B 7B 02 01 07 FA 7D 7D save as mode 8 7B 7B 02 01 08 FB 7D 7D save as mode 9 7B 7B 02 01 09 FC 7D 7D save as mode 10 7B 7B 02 01 0A FD 7D 7D save as mode 11 7B 7B 02 01 0B FE 7D 7D save as mode 12 7B 7B 02 01 0C F...
Страница 47: ...7B 7B 03 01 0F 03 7D 7D recall mode 16 7B 7B 03 01 10 04 7D 7D recall mode 17 7B 7B 03 01 11 05 7D 7D recall mode 18 7B 7B 03 01 15 09 7D 7D recall mode 22 7B 7B 03 01 16 0A 7D 7D recall mode 23 7B 7B 03 01 17 0B 7D 7D recall mode 24 7B 7B 03 01 18 0C 7D 7D recall mode 25 7B 7B 03 01 19 0D 7D 7D recall mode 26 7B 7B 03 01 1A 0E 7D 7D recall mode 27 7B 7B 03 01 1B 0F 7D 7D recall mode 28 Video Wall...
Страница 48: ...me Matrix Switch functions can be operated via remote control IR Route Switch From Output choose an output next from Input select an input Example OUT 1 IN 1 video from input 1 will come up on screen connected to output 1 ALL IN 1 video from input 1 will come up on all screens connected to the device Save Layouts From Function press save button next from Input select an input number Example SAVE I...
Страница 49: ...te the timely discharge of heat 4 Make sure the signal cable communication cable connects well to the matrix then power on AC power can t exceed 240V 5 Change the input source without turning off matrix may cause video to not display correctly If this occurs please turn off the matrix then power back on or re plug the input card 6 HDMI DVI cable should not exceed 10 meters certified cable is recom...
Страница 50: ... 025 SEADA Technology Ltd Oak Tree Park Burnt Meadow Road Moons Moat North Industrial Estate Redditch Worcestershire B98 9NW United Kingdom Email sales seada co uk Phone 44 0 1527 584364 Fax 44 0 1527 962998 ...