SC4x0 Technical manual
Page 14 of 34
SeaCom
Rev
2.00
5.1.5 E bank
This item shows current NOV memory error info. If a check sum error is detected in an eeprom
memory bank, error state is entered and the ID of the last failed bank will be shown here.
5.1.6 Error code
If an error is detected, a new entry is made to the error log and last entry is shown here. If the device is
giving error indication, the cause should be identified here.
Each system error has a unique binary indicator. If more errors are present, error code will represent
the sum of all errors. The value 0 is no errors.
E.g. if error 0x0001 and error 0x0002 is both active, error code will show 0003
Error code
Cause
Function
0001
RAM error
Set error state
0002
Check sum error
0004
NOV memory error
Set error state
0008
Temperature alarm
(set if board temp. >
80°C)
0010
Temperature warning
(set if board temp. >
70°C)
Switch off all backlight
Decrease speaker vol.
to step 7. (44%)
0020
No serial number
Set error state
0040
Watch dog error
Set error state
0080
IRQ time too long
5.2 Monitor line
This item will monitor all line events. This menu will not exit idle when hook off or timeout. It is possible
to press ‘Speaker’ to go off hook or to call the phone.
Following items will be monitored. Display will update on change only
Line voltage:
Numerical value from 0 to 63 volt.
Line polarity:
Tip > Ring : 1, If Ring > Tip : 2. NOTE Voltage must be out of 5V dead band.
Line
state:
-Idle
-busy
-ring
-NC
16 kHz signal: -Vol.
Indicating volume override (PA call).
-PA. Indicating normal PA call
-Term. Termination of ongoing sequence or cancel call.
-HOFF. Hook Off command (used for command / group call with direct in)
-HON. Hook On command (used for init of device or cancel command call)
-DIRECT Direct
in
call