SC4x0 Technical manual
Page 25 of 34
SeaCom
Rev
2.00
10.4 Parameter list for hidden menu
XX
number
Parameter Range
Notes
00
Relay hold off
0 – 10 sec.
(Factory setting: 0 );
Sets the time to hold relay between ring
signals.
01
Auto answer
0 - 50. 0=disabled.
(Factory setting: 0)
Sets the number of ringing signals before
auto answer.
02
16 kHz threshold
0- 100%
(Factory setting: 50%)
Sets the detector trigger point & should
ONLY be changed if problems with remote
control of device.
03
Temp. sensor offset. -12,7 - + 12,7 °C
(Factory setting: 0)
Used to compensate for offset error.
04
Temp. sensor gain
compensation
0 – 200%
(Factory setting: 100)
Used to compensate full range value. 100%
equals x1.00, 200% equals x2.00
05
Dimmer offset.
0-100%
(Factory setting: 0%)
Use to compensate for zero point failure.
06
Dimmer gain
0-200%
(Factory setting: 100%)
Used to compensate full range value. 100%
equals x1.00, 200% equals x2.00
07
Backlight ABS max.
0-100%.
(Factory setting: 100%)
Used to limit backlight intensity.
(Sets max endpoint of total span)
08
Backlight ABS min.
0-100%.
(Factory setting: 0%)
Used to prevent backlight from going total
off.
(Sets min endpoint of total span)
09
Max PA volume
0-17. Each step equals 3dB
(Factory setting: step 10)
Sets the volume used if PA call using
volume override is issued.
If set above step 11, gong sound may be
distorted)
(Normally used when priority PA or alarm
call)
10
DTMF to line gain
0-11. Each step equals 3dB
(Factory setting: step 10)
Sets the DTMF volume to the line
11
Audio to line gain
0-16. Each step equals 3dB
(Factory setting: step 15)
Sets the audio volume to the line.
12
UART speed
0 = Off
1 = 1200 baud
2 = 2400 baud
3 = 4800 baud
4 = 9600 baud
5 = 19.2kbd
6 = 38.4kbd
7 = 57.6kbd (Factory
setting)
8 = 115.2kbd
13
UART format
0 = Off
1 = 7bits, no parity, 1 stop
2 = 7bits, even parity, 1 stop
3 = 7bits, odd parity, 1 stop
4 = 8bits, no parity, 1 stop
5 = 8bits, even parity, 1 stop
6 = 8bits, odd parity, 1 stop